MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/icl.0000000000001014

Медицинская библиотека · Eye & contact lens · 2023

Baseline Characteristics of 1976 Patients With Ectatic Corneal Disorders at a Single Center From 2010 to 2021: A Cross-Sectional Study of the Homburg Keratoconus Center.

Sideroudi Haris, Flockerzi Elias, Daas Loay, Jullien Theresia, Xanthopoulou Kassandra, Hamon Loïc, Seitz Berthold

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

The study objective was to analyze the baseline characteristics of keratoconus (KC) patients at the Homburg Keratoconus Center from 2010 to 2021.

METHODS

This cross-sectional study included 3,674 eyes, with analysis of demographics, clinical findings, visual function, endothelial measurements, and topographic, tomographic, and corneal biomechanical data from the first visit.

RESULTS

Mean patient age was 36.3±13.8 years. The mean uncorrected distance visual acuity in log of minimal angle of resolution was 0.60 (20/80, Snellen equivalent), and the corrected mean was 0.3 (20/40). Of 1976 patients, 48.9% reported eye rubbing. Mean values (ranges) were 49.4±6.3 (36.3-78.0) D for steep keratometry, 462.4±66.0 (48.0-659.0) μm for thinnest corneal thickness, 9.7±8.7 (-0.5 to 88.8) for Belin/Ambrósio enhanced ectasia total deviation, 0.8±0.4 (0.0-1.0) for the Corvis biomechanical index, 0.9±0.2 (0.0-1.0) for the tomographic biomechanical index, 0.1±0.5 (-0.9 to 2.0) for the KC match index, 8.3±1.8 (2.2-17.7) mm Hg for corneal hysteresis, 7.1±2.2 (0.0-17.0) mm Hg for corneal resistance factor, and 2,562.9±326.3 (1,011-3,937) cells/mm2 for endothelial cell density. The average ABCDE KC stage was A2B3C1D1E2. Distance-corrected visual acuity correlated strongly with topometric, tomographic, and biomechanical data ( P <0.001).

CONCLUSIONS

This comprehensive description of baseline features of KC patients at a tertiary center provides a reference for further longitudinal and international multicentric studies.

Для цитирования: Sideroudi Haris, Flockerzi Elias, Daas Loay, Jullien Theresia, Xanthopoulou Kassandra, Hamon Loïc, Seitz Berthold. Baseline Characteristics of 1976 Patients With Ectatic Corneal Disorders at a Single Center From 2010 to 2021: A Cross-Sectional Study of the Homburg Keratoconus Center.. Eye & contact lens. 2023. DOI: 10.1097/icl.0000000000001014.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.