MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1039/d6an00698a

Медицинская библиотека · The Analyst · 2026

A novel electrochemical sensing platform based on highly crystalline covalent organic frameworks for the sensitive detection of rutin.

Deng Meng, Guo Hao, Yang Zeyun, Yan Ruixue, Ma Jianpeng, Niu Wenting, Kang Yujiao, Wang Mingyue, Yang Wu

СтатьяПеревод пока не подготовлен

Аннотация

Rutin (RT), a crucial flavonoid compound, exhibits significant physiological activities and medicinal value through its anti-tumor, anti-oxidation, and anti-inflammation effects, and cardiovascular protection. It is of great significance to develop an efficient and sensitive detection method for rutin. To achieve sensitive and rapid detection of rutin, this study constructs a novel composite-material electrochemical sensing platform based on a highly crystalline covalent organic framework (A-COF). The A-COF@NH2-MWCNT/GCE electrochemical sensor was successfully fabricated by preparing an in situ grown A-COF@NH2-MWCNT composite material to modify a glassy carbon electrode (GCE). Under the optimized experimental conditions, the electrochemical response of the sensor to rutin was investigated using the CV method and the DPV method. The results indicate that the constructed sensor exhibits satisfactory electrochemical characteristics, with a detection limit of 0.01 μM (S/N = 3) and a linear range of 0.2-170 μM. It also demonstrates good repeatability, reproducibility, stability, and anti-interference ability. The sensor was applied to detect rutin content in actual samples (human serum, urine, rutin tablets and buckwheat), and the results were accurate and reliable, with high recovery rates. This study offers a novel, simple and efficient electrochemical detection method for the trace analysis of rutin.

Для цитирования: Deng Meng, Guo Hao, Yang Zeyun, Yan Ruixue, Ma Jianpeng, Niu Wenting, Kang Yujiao, Wang Mingyue, Yang Wu. A novel electrochemical sensing platform based on highly crystalline covalent organic frameworks for the sensitive detection of rutin.. The Analyst. 2026. DOI: 10.1039/d6an00698a.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.