Redundant protective barriers: minimizing operator occupational risk.

Challa Karthik, Warren Stafford G, Danak Subhash, Bates Mark C

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

The ubiquitous use of less invasive therapeutic angiographic procedures has created the milieu for long-term occupational risk of cancer and genetic defects. This study set out to determine the relative effectiveness of redundant radiation protective barriers and their impact on operator total-body-ionizing radiation exposure in the catheterization suite.

METHODS

Thermolucent dosimeter x-irradiation was measured inside and outside personal and movable protective barriers used concurrently during 50 consecutive procedures by a single operator. Additionally, the entrance/exit doses were recorded on the back and chest for all patients to provide insight into radiation scatter patterns.

RESULTS

The x-ray beam had an average 90.8% decrement in energy traversing the patient's chest when entrance and exit doses were compared, suggesting a 3.3-fold greater operator scatter radiation exposure below the table compared with that above the table. All 0.5-mm lead equivalent personal barriers reduced operator exposure by 72-95%, whereas the 1.0-mm leaded personal barrier (overlapping gown) reduced exposure by 96%. The 0.75-mm leaded glasses reduced exposure to the left eye by 67%. A leaded left-hand glove reduced exposure by only 20%. The effective calculated operator radiation exposure risk reduction provided by the use of personal and movable barriers reduced the theoretical risk of fatal or nonfatal cancer by 22-fold while decreasing potential severe genetic effect by 25-fold in comparison to movable barriers alone.

CONCLUSIONS

The optimal use of combined personal and movable (redundant) lead barriers results in a significant reduction in total-body operator radiation exposure in the catheterization laboratory. The use of redundant barriers in the catheterization suite is associated with a dramatic theoretical long-term occupational risk reduction and should be encouraged.

Для цитирования: Challa Karthik, Warren Stafford G, Danak Subhash, Bates Mark C. Redundant protective barriers: minimizing operator occupational risk.. Journal of interventional cardiology. 2009. DOI: 10.1111/j.1540-8183.2009.00433.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.