Factors associated with corneal scarring in the Collaborative Longitudinal Evaluation of Keratoconus (CLEK) Study.

Barr J T, Zadnik K, Wilson B S, Edrington T B, Everett D F, Fink B A, Shovlin J P, Weissman B A, Siegmund K, Gordon M O

Сравнительное исследованиеОценочное исследованиеСтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАПоддержка службы здравоохранения СШАПеревод пока не подготовлен

Аннотация

PURPOSE: The multicenter Collaborative Longitudinal Evaluation of Keratoconus (CLEK) Study is a prospective, observational study of 1,209 keratoconus patients. We report on the factors associated with corneal scarring at baseline.

METHODS

We defined corneal scarring as scars that had been detected both by the clinician examining the patient with the slit-lamp biomicroscope and by masked readers of corneal photographs at the CLEK Photography Reading Center. We investigated associations between corneal scarring and patient variables including gender, ethnicity, a family history of keratoconus, a history of ocular trauma, eye rubbing, contact lens wear, rigid contact lens fitting relationships, and corneal findings (such as curvature, Vogt's striae, Fleischer's ring, and central/apical staining). Multiple logistic regression analysis using generalized estimating equations to adjust for the correlation between eyes was used for analysis.

RESULTS

The following factors were found to increase the odds of corneal scarring at baseline in the CLEK Study: corneal staining (odds ratios (OR) = 3.40, 95% confidence interval 2.53-4.59), contact lens wear (OR = 3.51, 95% confidence interval 2.27-5.45), Fleischer's ring (OR = 1.63, 95% confidence interval 1.11-2.40), steeper first definite apical clearance lens base curve radius (per diopter, OR = 1.29, 95% confidence interval 1.25-1.33), and age (per decade, OR = 1.54, 95% confidence interval 1.35-1.75).

CONCLUSIONS

These baseline data suggest that corneal scarring in keratoconus is associated with corneal staining, contact lens wear, Fleischer's ring, a steeper cornea, and increasing age. The factors that imply added risk for corneal scarring that may be affected by practitioner intervention are staining of the cornea, contact lens wear, and the contact lens fitting relationship.

Для цитирования: Barr J T, Zadnik K, Wilson B S, Edrington T B, Everett D F, Fink B A, Shovlin J P, Weissman B A, Siegmund K, Gordon M O. Factors associated with corneal scarring in the Collaborative Longitudinal Evaluation of Keratoconus (CLEK) Study.. Cornea. 2000. DOI: 10.1097/00003226-200007000-00020.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.