m+Medelevator.RU
← Поиск публикаций
The American journal of clinical nutrition · 2024

Can sodium and potassium measured in timed voids be used as reference instruments for validating self-report instruments? Results from a urine calibration study.

СтатьяПоддержка NIH: внешняя программаВалидационное исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Freedman Laurence S, Wang Chia-Yih, Commins John, Barrett Brian, Midthune Douglas, Dodd Kevin W, Carroll Raymond J, Kipnis Victor

Аннотация

BACKGROUND: Sodium and potassium measured in 24-h urine collections are often used as reference measurements to validate self-reported dietary intake instruments.

OBJECTIVES: To evaluate whether collection and analysis of a limited number of urine voids at specified times during the day ("timed voids") can provide alternative reference measurements, and to identify their optimal number and timing.

METHODS: We used data from a urine calibration study among 441 adults aged 18-39 y. Participants collected each urine void in a separate container for 24 h and recorded the collection time. For the same day, they reported dietary intake using a 24-h recall. Urinary sodium and potassium were analyzed in a 24-h composite sample and in 4 timed voids (morning, afternoon, evening, and overnight). Linear regression models were used to develop equations predicting log-transformed 24-h urinary sodium or potassium levels using each of the 4 single timed voids, 6 pairs, and 4 triples. The equations also included age, sex, race, BMI (kg/m2), and log creatinine. Optimal combinations minimizing the mean squared prediction error were selected, and the observed and predicted 24-h levels were then used as reference measures to estimate the group bias and attenuation factors of the 24-h dietary recall. These estimates were compared.

RESULTS: Optimal combinations found were as follows: single voids-evening; paired voids-afternoon + overnight (sodium) and morning + evening (potassium); and triple voids-morning + evening + overnight (sodium) and morning + afternoon + evening (potassium). Predicted 24-h urinary levels estimated 24-h recall group biases and attenuation factors without apparent bias, but with less precision than observed 24-h urinary levels. To recover lost precision, it was estimated that sample sizes need to be increased by ∼2.6-2.7 times for a single void, 1.7-2.1 times for paired voids, and 1.5-1.6 times for triple voids.

CONCLUSIONS: Our results provide the basis for further development of new reference biomarkers based on timed voids.

CLINICAL TRIAL REGISTRY: clinicaltrials.gov as NCT01631240.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты