MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/s0161-6420(95)30806-8

Медицинская библиотека · Ophthalmology · 1995

Full-thickness macular hole formation in eyes with a pre-existing complete posterior vitreous detachment.

Gordon L W, Glaser B M, Ie D, Thompson J T, Sjaarda R N

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Tangential macular traction by the posterior vitreous cortex has been widely accepted as the major causative factor in the development of idiopathic macular holes. Separation of the posterior cortical vitreous should relieve this vitreoretinal traction.

METHODS

The authors report five patients with idiopathic full-thickness macular hole formation that occurred in the presence of a well-documented pre-existing complete posterior vitreous detachment.

RESULTS

Of five eyes, three underwent pars plana vitrectomy and instillation of transforming growth factor-beta. No residual prefoveal cortical vitreous was present at the retinal surface at the time of surgery. Additionally, clinically identifiable epiretinal membranes were present in three of five eyes, but these epiretinal membranes were extremely thin, transparent, induced minimal traction, and did not warrant surgical peeling.

CONCLUSION

It is likely that, in these five patients, some mechanism other than tangential traction by prefoveal vitreous cortex is responsible for idiopathic full-thickness macular hole formation.

Для цитирования: Gordon L W, Glaser B M, Ie D, Thompson J T, Sjaarda R N. Full-thickness macular hole formation in eyes with a pre-existing complete posterior vitreous detachment.. Ophthalmology. 1995. DOI: 10.1016/s0161-6420(95)30806-8.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.