MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00590-022-03439-0

Медицинская библиотека · European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2022

Clinical and radiological outcomes of total hip arthroplasty in octogenarian patients using a three-dimensional porous titanium cup: a retrospective analysis in Japanese patients.

Kaneko Taizo, Nakamura Shinya, Hayakawa Kentaro, Tokimura Fumiaki, Miyazaki Tsuyoshi

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: Osteointegration of a three-dimensional (3D) porous titanium material has been experimentally proven, but only a few studies have shown the clinical outcomes of a 3D porous titanium cup in the Japanese elderly population. The purpose of this study was to compare the short-and-medium term clinical and radiographic results of total hip arthroplasty (THA) using a 3D porous titanium cup in patients aged ≥ 80 (octogenarians) versus those aged < 80 (younger controls).

METHODS

A total of 104 hips that underwent THA using a 3D porous titanium cup (SQRUM TT, Kyocera Medical) were enrolled in the study and were divided into two groups according to age: the octogenarian group (≥ 80, n = 42) and the younger control group (< 80, n = 62). Furthermore, we evaluated patient characteristics, clinical outcomes determined by the Japanese Orthopedic Association score, cup alignment, and incidence of radiolucent lines around the cup.

RESULTS

The mean follow-up period was 4.2 and 4.0 years (p = 0.29) for octogenarians and younger controls, respectively. The clinical outcomes were excellent, and no revision surgery occurred until the last follow-up in both groups. The number of patients with radiolucent lines at the final evaluation was 21 of 62 (33.9%) in younger controls and 16 of 42 (38.1%) in octogenarians.

CONCLUSION

THA with 3D porous titanium cup for octogenarians had similar clinical outcomes and incidence of radiolucent lines as those of younger controls, suggesting that the 3D porous titanium cup may be useful in THA for octogenarians. Further investigations will confirm its long-term outcomes.

Для цитирования: Kaneko Taizo, Nakamura Shinya, Hayakawa Kentaro, Tokimura Fumiaki, Miyazaki Tsuyoshi. Clinical and radiological outcomes of total hip arthroplasty in octogenarian patients using a three-dimensional porous titanium cup: a retrospective analysis in Japanese patients.. European journal of orthopaedic surgery & traumatology : orthopedie traumatologie. 2022. DOI: 10.1007/s00590-022-03439-0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.