MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jvir.2022.10.020

Медицинская библиотека · Journal of vascular and interventional radiology : JVIR · 2022

Stent Graft Placement for the Treatment of Hepatic Artery Injury in Patients with Cancer: Primary Patency and Clinical Outcomes.

Aly Ahmed K, Yarmohammadi Hooman, Bajwa Raazi, Silk Mikhail, Hsu Meier, Moskowitz Chaya, Santos Ernesto, Moussa Amgad M

СтатьяПоддержка NIH: внешняя программаПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate the safety, primary patency, and clinical outcomes of hepatic artery stent graft (SG) placement for vascular injuries.

MATERIALS AND

METHODS

Patients treated with hepatic arterial SG placement for vascular injuries between September 2018 and September 2021 were reviewed. Data on demographic characteristics, indication, stent graft characteristics, antiplatelet/anticoagulant use, clinical success rate, complications, and type of follow-up imaging were collected. Follow-up images were reviewed by 2 independent reviewers to assess primary patency. A time-to-event analysis was performed. The median duration of stent graft patency was estimated using Kaplan-Meier curves. A Cox proportional hazard model was used to evaluate factors related to stent graft patency.

RESULTS

Thirty-five patients were treated with hepatic arterial SG placement, 11 for postoperative bleeds and 24 for hepatic artery infusion pump catheter-related complications. Clinical success was achieved in 32 (91%) patients (95% CI, 77-98). The median primary patency was 87 days (95% CI, 73-293). Stent grafts of ≥6-mm diameter retained patency for a longer duration than that with stent grafts of smaller diameters (6 mm vs 5 mm; hazard ratio, 0.35; 95% CI, 0.14-0.88; P = .026; and 7+ mm vs 5 mm; hazard ratio, 0.27; 95% CI, 0.09-0.83; P = .023). Anticoagulation/antiplatelet regimen was not associated with increased stent graft patency duration (P > .05). Only minor complications were reported in 2 (5.7%) patients.

CONCLUSIONS

Stent grafts can be used safely and effectively to treat injuries of the hepatic artery. Stent graft diameters of ≥6 mm seem to provide more durable patency.

Для цитирования: Aly Ahmed K, Yarmohammadi Hooman, Bajwa Raazi, Silk Mikhail, Hsu Meier, Moskowitz Chaya, Santos Ernesto, Moussa Amgad M. Stent Graft Placement for the Treatment of Hepatic Artery Injury in Patients with Cancer: Primary Patency and Clinical Outcomes.. Journal of vascular and interventional radiology : JVIR. 2022. DOI: 10.1016/j.jvir.2022.10.020.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.