MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1056/nejmoa2005206

Медицинская библиотека · The New England journal of medicine · 2020

Mortality with Paclitaxel-Coated Devices in Peripheral Artery Disease.

Nordanstig Joakim, James Stefan, Andersson Manne, Andersson Mattias, Danielsson Peter, Gillgren Peter, Delle Martin, Engström Jan, Fransson Torbjörn, Hamoud Maher, Hilbertson Anna, Johansson Patrik, Karlsson Lars, Kragsterman Björn, Lindgren Hans, Ludwigs Karin, Mellander Stefan, Nyman Niklas, Renlund Henrik, Sigvant Birgitta, Skoog Per, Starck Joachim, Tegler Gustaf, Toivola Asko, Truedson Maria, Wahlgren Carl-Magnus, Wallinder Jonas, Öjersjö Andreas, Falkenberg Mårten

Сравнительное исследованиеСтатьяМногоцентровое исследованиеРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

The results of a recent meta-analysis aroused concern about an increased risk of death associated with the use of paclitaxel-coated angioplasty balloons and stents in lower-limb endovascular interventions for symptomatic peripheral artery disease.

METHODS

We conducted an unplanned interim analysis of data from a multicenter, randomized, open-label, registry-based clinical trial. At the time of the analysis, 2289 patients had been randomly assigned to treatment with drug-coated devices (the drug-coated-device group, 1149 patients) or treatment with uncoated devices (the uncoated-device group, 1140 patients). Randomization was stratified according to disease severity on the basis of whether patients had chronic limb-threatening ischemia (1480 patients) or intermittent claudication (809 patients). The single end point for this interim analysis was all-cause mortality.

RESULTS

No patients were lost to follow-up. Paclitaxel was used as the coating agent for all the drug-coated devices. During a mean follow-up of 2.49 years, 574 patients died, including 293 patients (25.5%) in the drug-coated-device group and 281 patients (24.6%) in the uncoated-device group (hazard ratio, 1.06; 95% confidence interval, 0.92 to 1.22). At 1 year, all-cause mortality was 10.2% (117 patients) in the drug-coated-device group and 9.9% (113 patients) in the uncoated-device group. During the entire follow-up period, there was no significant difference in the incidence of death between the treatment groups among patients with chronic limb-threatening ischemia (33.4% [249 patients] in the drug-coated-device group and 33.1% [243 patients] in the uncoated-device group) or among those with intermittent claudication (10.9% [44 patients] and 9.4% [38 patients], respectively).

CONCLUSIONS

In this randomized trial in which patients with peripheral artery disease received treatment with paclitaxel-coated or uncoated endovascular devices, the results of an unplanned interim analysis of all-cause mortality did not show a difference between the groups in the incidence of death during 1 to 4 years of follow-up. (Funded by the Swedish Research Council and others; ClinicalTrials.gov number, NCT02051088.).

Для цитирования: Nordanstig Joakim, James Stefan, Andersson Manne, Andersson Mattias, Danielsson Peter, Gillgren Peter, Delle Martin, Engström Jan, Fransson Torbjörn, Hamoud Maher, Hilbertson Anna, Johansson Patrik, Karlsson Lars, Kragsterman Björn, Lindgren Hans, Ludwigs Karin, Mellander Stefan, Nyman Niklas, Renlund Henrik, Sigvant Birgitta, Skoog Per, Starck Joachim, Tegler Gustaf, Toivola Asko, Truedson Maria, Wahlgren Carl-Magnus, Wallinder Jonas, Öjersjö Andreas, Falkenberg Mårten. Mortality with Paclitaxel-Coated Devices in Peripheral Artery Disease.. The New England journal of medicine. 2020. DOI: 10.1056/nejmoa2005206.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.