MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.amjcard.2020.01.008

Медицинская библиотека · The American journal of cardiology · 2020

Novel Anatomic Predictors of New Persistent Left Bundle Branch Block After Evolut Transcatheter Aortic Valve Implantation.

Zaid Syed, Sengupta Aditya, Okoli Kimberly, Tsoi Melissa, Khan Asaad, Ahmad Hasan, Goldberg Joshua B, Undemir Cenap, Rozenshtein Anna, Patel Nish, Khan Muhammad, Gupta Eisha, Kovacic Jason, Lansman Steven L, Dangas George D, Sharma Samin K, Kini Annapoorna, Tang Gilbert H L

СтатьяПеревод пока не подготовлен

Аннотация

New persistent left bundle branch block (NP-LBBB) has been associated with adverse outcomes after TAVI but few predictors thus far reported. We sought to identify predictors of NP-LBBB after TAVI with EvolutR/PRO (ER/EP). From 1/2016 to 4/2019, 544 patients from 2 centers underwent TAVI with Evolut (54% ER, 46% EP) for severe native aortic stenosis. Patients with previous LBBB and pacemaker were excluded. Aortic root analysis was performed using 3Mensio Valves Software and membranous septal length (MSL) was determined using the standard coronal view. Clinical, anatomic and procedural characteristics of 396 Evolut were analyzed and predictors of NP-LBBB were identified. Valve Academic Research Consortium-2 outcomes were reported. At discharge, NP-LBBB was seen in 76(19.2%) patients. NP-LBBB in Evolut was associated with implant depth at left coronary cusp (p = 0.004) and 34 mm ER (p = 0.026). Independent predictors of NP-LBBB in Evolut were shorter MSL (odds ratio [OR] = 0.82 per mm septum, 95% confidence interval [CI] = 0.68 to 0.98,p = 0.030), left ventricular outflow tract (LVOT) eccentricity (OR = 1.04 per %, 95% CI = 1.01 to 1.06,p = 0.002), implant depth at noncoronary cusp (NCC) (OR = 1.28 per mm ventricular, 95% CI = 1.11 to 1.48,p = 0.001) and annular perimeter oversizing ≥20% (OR = 2.38, 95% CI = 1.20 to 4.72, p = 0.013). On ROC curve analysis, MSL ≤6.5 mm, NCC depth ≥3 mm and LVOT eccentricity ≥35% were optimal threshold values to predict NP-LBBB. In Conclusion, shorter MSL, LVOT eccentricity, annular oversizing and deeper implant depth are novel predictors of NP-LBBB in Evolut TAVI. Preprocedural CT assessment of aortic root anatomy may help identify patients at risk for NP-LBBB. In such patients, modifying procedural factors such as higher implant and less annular oversizing may reduce the risk of NP-LBBB. Further evaluation of our hypothesis is warranted.

Для цитирования: Zaid Syed, Sengupta Aditya, Okoli Kimberly, Tsoi Melissa, Khan Asaad, Ahmad Hasan, Goldberg Joshua B, Undemir Cenap, Rozenshtein Anna, Patel Nish, Khan Muhammad, Gupta Eisha, Kovacic Jason, Lansman Steven L, Dangas George D, Sharma Samin K, Kini Annapoorna, Tang Gilbert H L. Novel Anatomic Predictors of New Persistent Left Bundle Branch Block After Evolut Transcatheter Aortic Valve Implantation.. The American journal of cardiology. 2020. DOI: 10.1016/j.amjcard.2020.01.008.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.