m+Medelevator.RU
← Поиск публикаций
Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2017

Left ventricular dysfunction is related to the presence and extent of a septal flash in patients with right ventricular pacing.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Sarvari Sebastian Imre, Sitges Marta, Sanz Maria, Tolosana Viu Jose Maria, Edvardsen Thor, Stokke Thomas Muri, Mont Lluis, Bijnens Bart

Аннотация

AIMS: Septal flash (SF), a marker of left ventricular (LV) dyssynchrony in the presence of a left bundle branch block (LBBB), has been shown to predict improved ventricular function and outcome when corrected with cardiac resynchronization therapy. We hypothesized that a SF is present in patients receiving right ventricular (RV) pacing and its presence and extent could predict the development of LV dysfunction and remodelling.

METHODS AND RESULTS: Seventy-four consecutive patients receiving conventional RV pacing (>6 months, >85% paced) were studied with two-dimensional (2D) echocardiography. Indications for pacing were sinus-node dysfunction and atrioventricular conduction disorders. The presence of a SF was determined on stepwise advanced 2D echocardiographic views and confirmed using greyscale M-mode. Septal flash excursion was quantified by the amplitude of the early inward motion, measured from QRS onset to maximal inward motion. Fifty-seven (of 74; 77%) patients receiving RV pacing had a detectable SF. Patients with a SF had lower LV ejection fraction (EF) (52 ± 10 vs. 60 ± 4%, P < 0.001) and greater indexed end-systolic volume (33 ± 16 vs. 23 ± 5 mL/m2, P < 0.001). Receiver operating characteristic analysis demonstrated that a SF of 3.5 mm was the optimal cut-off value (area under the curve = 0.95) to identify reduced LV function (EF < 50%) with a sensitivity of 91% and a specificity of 90%.

CONCLUSION: A SF was present in a majority of patients receiving conventional RV pacing and its magnitude was related to LV dysfunction and adverse remodelling. Given the similarities observed in LBBB and pacemaker-induced dyssynchrony, SF magnitude might be a predictor for the development of LV dysfunction and adverse remodelling in patients receiving conventional RV pacing.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты