MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/europace/euw156

Медицинская библиотека · Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2017

Reduction of falls and fractures after permanent pacemaker implantation in elderly patients with sinus node dysfunction.

Brenner Roman, Ammann Peter, Yoon See-Il, Christen Stefan, Hellermann Jens, Girod Grégoire, Knaus Urs, Duru Firat, Krasniqi Nazmi, Ramsay David, Sticherling Christian, Lippuner Kurt, Kühne Michael

СтатьяМногоцентровое исследованиеНаблюдательное исследованиеПеревод пока не подготовлен

Аннотация

AIMS: Elderly patients with sinus node dysfunction (SND) are at increased risk of falls with possible injuries. However, the incidence of these adverse events and its reduction after permanent pacemaker (PPM) implantation are not known.

METHODS AND

RESULTS

Eighty-seven patients (mean [SD] age 75.4 [8.3] years, 51% women) with SND and an indication for cardiac pacing were included and were examined by a standardized interview targeting fall history. The incidence and total number of falls, falls with injury, falls requiring treatment, and falls resulting in a fracture were assessed for the time period of 12 months before (retrospectively) and after PPM implantation (prospectively). Furthermore, symptoms such as syncope, dizziness, and dyspnea were evaluated before and after PPM implantation. The implantation of a PPM was associated with a reduced proportion of patients experiencing at least one fall by 71% (from 53 to 15%, P < 0.001) and a reduction of the absolute number of falls by 90% (from 127 to 13, P < 0.001) during the 12 months before vs. after PPM implant. Falls with injury (28 vs. 10%, P = 0.005), falls requiring medical attention (31 vs. 8%, P < 0.001), and falls leading to fracture (8 vs. 0%, P = 0.013) were similarly reduced. Notably, fewer patients had syncope (4 vs. 45%, P < 0.001) and dizziness after PPM implantation (12 vs. 45%, P < 0.001).

CONCLUSION

Falls, fall-related injuries, and fall-related fractures are frequent in SND patients. Permanent pacemaker implantation is associated with a significantly reduced risk of these adverse events, although no causal relationship could be established due to the study design.

Для цитирования: Brenner Roman, Ammann Peter, Yoon See-Il, Christen Stefan, Hellermann Jens, Girod Grégoire, Knaus Urs, Duru Firat, Krasniqi Nazmi, Ramsay David, Sticherling Christian, Lippuner Kurt, Kühne Michael. Reduction of falls and fractures after permanent pacemaker implantation in elderly patients with sinus node dysfunction.. Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology. 2017. DOI: 10.1093/europace/euw156.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.