Safety and efficiency of ventricular pacing prevention with an AAI-DDD changeover mode in patients with sinus node disease or atrioventricular block: impact on battery longevity-a sub-study of the ANSWER trial.
СтатьяМногоцентровое исследованиеРандомизированное исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Stockburger Martin, Defaye Pascal, Boveda Serge, Stancak Branislav, Lazarus Arnaud, Sipötz Johann, Nardi Stefano, Rolando Mara, Moreno Javier
Аннотация
AIMS: This ANSWER (EvaluAtioN of the SafeR mode in patients With a dual chambER pacemaker indication) sub-study assesses safety and effectiveness of SafeR™ and the impact of ventricular pacing (VP) prevention on anticipated device longevity and replacement rate.
METHODS AND RESULTS: Patients implanted for atrioventricular block (AVB, n = 310) or sinus node dysfunction (SND, n = 336) were randomly assigned to SafeR (n = 314) or DDD (n = 318) and followed for 36 months. Safety, median VP, estimated device longevity (mean difference, 95% confidence interval [CI]), and anticipated replacement rates were analysed by pacing mode and implant indication. No difference in mortality, syncope, or mode intolerance was observed between randomization groups regardless of the indication. Ventricular pacing on SafeR vs. DDD was 11.5 vs. 93.6% in the overall population (P < 0.001), 89.2 vs. 83.8% in permanent AVB (P = 0.944), 53.5 vs. 98.2% in intermittent AVB (P < 0.001), and 2.2 vs. 84.7% in SND (P < 0.001). Anticipated median device longevity increased on SafeR by 14 [Q1 10; Q3 17] months [10; 17] (P < 0.001) in the overall population, 9 months [-5; 22] (P = 0.193) in permanent AVB, 14 months [8; 19] (P < 0.001) in intermittent AVB, and 14 months [9; 19] (P < 0.001) in SND. In intermittent AVB and SND, prolonged estimated battery longevity translated into the prevention of one anticipated replacement in at least 23% of patients.
CONCLUSION: SafeR was effective in reducing VP in intermittent AVB and in SND. No effect was observed in permanent AVB. No safety issue was observed. Ventricular pacing reduction by SafeR translated into relevant estimated prolongation of device longevity and anticipated reduction of required replacements.
METHODS AND RESULTS: Patients implanted for atrioventricular block (AVB, n = 310) or sinus node dysfunction (SND, n = 336) were randomly assigned to SafeR (n = 314) or DDD (n = 318) and followed for 36 months. Safety, median VP, estimated device longevity (mean difference, 95% confidence interval [CI]), and anticipated replacement rates were analysed by pacing mode and implant indication. No difference in mortality, syncope, or mode intolerance was observed between randomization groups regardless of the indication. Ventricular pacing on SafeR vs. DDD was 11.5 vs. 93.6% in the overall population (P < 0.001), 89.2 vs. 83.8% in permanent AVB (P = 0.944), 53.5 vs. 98.2% in intermittent AVB (P < 0.001), and 2.2 vs. 84.7% in SND (P < 0.001). Anticipated median device longevity increased on SafeR by 14 [Q1 10; Q3 17] months [10; 17] (P < 0.001) in the overall population, 9 months [-5; 22] (P = 0.193) in permanent AVB, 14 months [8; 19] (P < 0.001) in intermittent AVB, and 14 months [9; 19] (P < 0.001) in SND. In intermittent AVB and SND, prolonged estimated battery longevity translated into the prevention of one anticipated replacement in at least 23% of patients.
CONCLUSION: SafeR was effective in reducing VP in intermittent AVB and in SND. No effect was observed in permanent AVB. No safety issue was observed. Ventricular pacing reduction by SafeR translated into relevant estimated prolongation of device longevity and anticipated reduction of required replacements.