m+Medelevator.RU
← Поиск публикаций
Annals of noninvasive electrocardiology : the official journal of the International Society for Holter and Noninvasive Electrocardiology, Inc · 2014

Ambulatory electrocardiographic monitoring between artifacts and misinterpretation, management errors of commission and errors of omission.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

El-Sherif Nabil, Turitto Gioia

Аннотация

BACKGROUND: The aim of the study is to contrast the role of conventional ambulatory electrocardiographic monitoring (AEM) artifacts with a less emphasized problem with potentially more serious implications, that is, the failure to recognize, and therefore misinterpret, a genuine arrhythmia episode in the AEM recording.

METHODS: The study material included 500 Holter recordings and 500 recordings from the cardiac telemetry unit.

RESULTS: Electrocardiographic (ECG) artifacts were more common in telemetry recordings (5.6%) compared to Holter recordings (4%) for a total of 4.8%. There were 35 examples of misinterpretation of AEM recordings (3.5%). These were significantly more common in telemetry recordings (2.6%) compared to Holter recordings (0.9%). The most common ECG artifacts were examples of pseudo ventricular tachyarrhythmia (VT). The majority of misinterpretation (26 of 35 examples) were fast supraventricular tachyarrhythmias with aberrant QRS (including six examples of atrial flutter with periods of 1:1 atrioventricular conduction) that were misdiagnosed as ventricular VT. Other examples were misinterpretation of arrhythmic episodes consistent with sick sinus syndrome, pacemaker malfunction, and long QT syndrome. Only 5 of 48 examples of AEM artifacts resulted in management errors of commission or errors of omission compared to all 35 examples of misinterpretation.

CONCLUSIONS: Compared to conventional artifacts in AEM, misinterpretation of nonartifactual arrhythmic episodes consistently resulted in management errors. Misinterpretation was significantly more common with telemetry recordings compared to Holter ECG. This highlights the need for more appropriate training of the entire clinical team in charge of the management of the cardiac telemetry unit.