Spanish pacemaker registry. 10th official report of the Spanish Society of Cardiology Working Group on Cardiac Pacing (2012).

Coma Samartín Raúl, Ruiz Mateas Francisco, Fidalgo Andrés María Luisa, Leal del Ojo González Juan, Pérez Álvarez Luisa

СтатьяМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

INTRODUCTION AND

OBJECTIVES

Our aim was to analyze the pacemaker implantations and replacements reported to the Spanish Pacemaker Registry in 2012 with special reference to the selection of pacing modes.

METHOD: The analysis was based on information provided by the European Pacemaker Patient Identification Card.

RESULTS

Data were received from 115 hospitals, with a total of 12 856 cards. An estimated 745.8 pacemaker generators and 53.1 resynchronization devices were implanted per million population. Active fixation leads were implanted in more than 70% of the patients; of these leads, more than 20% were safe for use with magnetic resonance. The most common electrocardiographic indication for pacemaker implantation was atrioventricular block (56%). In all, 28% of the patients with sick sinus syndrome were paced in VVIR mode.

CONCLUSIONS

The use of conventional pacemakers remained stable, whereas the implantation of resynchronization devices increased. Active fixation leads are now employed in most patients. The findings of this study confirm the higher incidence of implantation in men and at an earlier age due to the higher rate of conduction disorders. Age is a factor that influences the choice of the appropriate pacing mode.

Для цитирования: Coma Samartín Raúl, Ruiz Mateas Francisco, Fidalgo Andrés María Luisa, Leal del Ojo González Juan, Pérez Álvarez Luisa. Spanish pacemaker registry. 10th official report of the Spanish Society of Cardiology Working Group on Cardiac Pacing (2012).. Revista espanola de cardiologia (English ed.). 2013. DOI: 10.1016/j.rec.2013.08.007.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.