AIMS: The present study was to assess the reduction of right ventricular pacing (RVP) by pacemaker algorithms of Managed Ventricular Pacing (MVP) and Search AV+ (SAV+) interval over a period of 12 months.

METHODS AND

RESULTS

A total of 385 patients indicated for a dual-chamber pacemaker (DC-PM) were enrolled in the prospective, randomized COMPARE study at 29 centres in China between June 2009 and April 2011. Patients implanted with DC-PMs were randomized in a 1 : 1 ratio to the MVP group or the SAV+ group. The percentage of VP (%VP) was obtained from the device diagnostic data at 1-, 6-, and 12-month follow-ups and was expressed as the median %VP over all beats in patients with sinus node dysfunction (SND) and atrioventricular block (AVB) excluding persistent third-degree AVB. Of 385 enrolled patients, 253 had SND and 72 had AVB. The %VP in the MVP group was significantly lower than that in the SAV+ group at 1-, 6-, and 12-month follow-ups, respectively. At 12-month follow-up, the median %VP in SND patients was 0.20% in the MVP group and 1.4% in the SAV+ group (P < 0.0001) and the median %VP in AVB patients was 11.8% in the MVP group and 98.1% in the SAV+ group (P < 0.001). There was no statistical difference in %VP from 1- to 12-month follow-up. A trend in the correlation between %VP and AT/AF burden was observed.

CONCLUSION

Over 12-month follow-up, the %VP was lower for MVP than SAV+ in patients with either SND or AVB. The sustainable %VP reduction has potential implications in reducing the development of heart failure and/or atrial arrhythmia morbidity.

Для цитирования: Chen Silin, Chen Keping, Tao Qianmin, Zheng Liangrong, Shen Farong, Wu Shulin, Fan Jie, Xu Geng, Wang Li, Zhou Xiaohong, Zhang Shu, COMPARE Study Investigators. Reduction of unnecessary right ventricular pacing by managed ventricular pacing and search AV+ algorithms in pacemaker patients: 12-month follow-up results of a randomized study.. Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology. 2014. DOI: 10.1093/europace/euu055.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.