The OPTI-MIND study: a prospective, observational study of pacemaker patients according to pacing modality and primary indications.

Biffi Mauro, Melissano Donato, Rossi Paolo, Kaliska Gabriela, Havliĉek Aleš, Pelargonio Gemma, Romero Rafael, Guastaferro Ciro, Menichelli Maurizio, Vireca Elisa, Frisoni Jessica, Boriani Giuseppe, Malacky Tibor

СтатьяНаблюдательное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

AIMS: The OPTI-MIND study aims to collect 2-year clinical outcomes of pacemaker patients in real-world clinical practice, overall and according to patient characteristics and pacemaker settings.

METHODS AND

RESULTS

The present analysis of the OPTI-MIND study describes the programmed device settings after discharge from the pacemaker implant. The objective was to determine whether these settings fit recent guidelines for device-programmed physiological pacing based on the preservation of atrioventricular synchrony, avoiding unnecessary pacing, ensuring rate increase during exercise or preventing neurally mediated symptoms. A total of 1740 patients were enroled at 68 centres worldwide. Baseline patient characteristics and device programming settings are available in 1674 of 1740 patients (96%). Guidelines to ensure physiological pacing were followed in 41% of patients: in patients with sinus node disease (SND), and without atrioventricular block (AVB), device programming could have led to unnecessary right ventricular pacing in 38% of patients. In SND patients with chronotropic incompetence, assisted rate increase during exercise was not programmed in 42% of patients. In 11% of patients with AVB, atrioventricular (AV) synchrony was not pursued; the main drivers being advanced age and history of atrial fibrillation. Patients with both SND and AVB were generally programmed physiologically (87%).

CONCLUSION

The present analysis showed that frequent deviations occurred when comparing the device settings at discharge from the pacemaker implant in clinical practice to the available guidelines on pacing mode selection. Analysis of 2-year outcomes in the OPTI-MIND study will provide an insight into whether specific physiological settings could improve the quality of pacing with a positive effect on patient outcome.

Для цитирования: Biffi Mauro, Melissano Donato, Rossi Paolo, Kaliska Gabriela, Havliĉek Aleš, Pelargonio Gemma, Romero Rafael, Guastaferro Ciro, Menichelli Maurizio, Vireca Elisa, Frisoni Jessica, Boriani Giuseppe, Malacky Tibor. The OPTI-MIND study: a prospective, observational study of pacemaker patients according to pacing modality and primary indications.. Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology. 2014. DOI: 10.1093/europace/eut387.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.