Clinical impact of the implantable loop recorder in patients with isolated syncope, bundle branch block and negative workup: a randomized multicentre prospective study.

Da Costa Antoine, Defaye Pascal, Romeyer-Bouchard Cécile, Roche Frédéric, Dauphinot Virginie, Deharo Jean-Claude, Jacon Peggy, Lamaison Dominique, Bathélemy Jean-Claude, Isaaz Karl, Laurent Gabriel

Сравнительное исследованиеСтатьяМногоцентровое исследованиеРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Few studies have compared conventional testing with prolonged monitoring using an implantable loop recorder (ILR) following the first syncope episode in patients with bundle branch block (BBB) and negative workup.

OBJECTIVES

To compare two syncope evaluation strategies-primary use of an ILR (Group 1) versus conventional testing (Group 2)-and to estimate the prevalence of significant arrhythmias in the ILR patient subset.

METHODS

From January 2005 to December 2010, 78 patients admitted after one syncope episode were randomized to ILR (n=41) or conventional follow-up (n=37). Mean follow-up was 27 ± 12 months.

RESULTS

Mean age was 76 ± 8 years and 30 patients were women (38.5%); 18 presented cardiomyopathy (23%) and 12 had a history of atrial fibrillation (15.4%). Mean left ventricular ejection fraction was 56.5 ± 11% and mean His-to-ventricle interval was 55 ± 6ms based on negative electrophysiological study (EPS). Electrocardiogram abnormalities involved: 34 left bundle branch blocks (BBBs); 11 right BBBs; and 33 bifascicular blocks. Overall, 21 patients (27%) developed significant arrhythmic events: ventricular tachycardia (n=1; 1.3%); sudden death (n=2; 2.6%); third-degree atrioventricular (AV) block (n=14; 18%); sick sinus syndrome (n=4; 5.1%). In 19 (24.4%) patients, relevant arrhythmias were detected, with a significant difference between the ILR group (n=15/41; 36.6%) and the conventional follow-up group (n=4/37; 10.8%) (P=0.02). Eighteen patients were implanted with pacemakers; one received an implantable defibrillator. No predictors of AV block were identified in the ILR group.

CONCLUSIONS

In this randomized prospective study, the ILR strategy proved largely superior to conventional follow-up in detecting recurrent events, with a potential impact on therapeutic management. This observation highlights the usefulness of early monitoring in patients with BBB and negative EPS even after the first syncope episode but an empiric pacemaker strategy remains to be validated in this selected population.

Для цитирования: Da Costa Antoine, Defaye Pascal, Romeyer-Bouchard Cécile, Roche Frédéric, Dauphinot Virginie, Deharo Jean-Claude, Jacon Peggy, Lamaison Dominique, Bathélemy Jean-Claude, Isaaz Karl, Laurent Gabriel. Clinical impact of the implantable loop recorder in patients with isolated syncope, bundle branch block and negative workup: a randomized multicentre prospective study.. Archives of cardiovascular diseases. 2013. DOI: 10.1016/j.acvd.2012.12.002.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.