DOI 10.1007/s00402-020-03438-y

Медицинская библиотека · Archives of orthopaedic and trauma surgery · 2020

Comparing iatrogenic radial nerve lesions in humeral shaft fractures treated with helical or straight PHILOS plates: a 10-year retrospective cohort study of 62 cases.

Da Silva Tomas, Rummel Franziska, Knop Christian, Merkle Tobias

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Humerus shaft fractures are common and often treated surgically with a proximal humerus internal locking system like the long PHILOS® plate. Due to its close anatomical proximity to the humerus, the radial nerve is particularly susceptible to traumatic and iatrogenic damage. The iatrogenic radial nerve damage associated with internal locking systems is described in about 7% of the cases. In order to avoid this lesion, helical plates have been suggested since 1999. This technique continues to not being used as standard as there is still a clear lack of evidence. This study aimed to understand if twisting a long PHILOS plate can reduce the rate of iatrogenic radial nerve damage in humerus shaft fractures.

METHODS

In this 10-year retrospective comparative study, patients with primary traumatic proximal humerus shaft fracture treated with a straight or twisted helical PHILOS® plate were analyzed and compared. Among the 62 patients meeting the inclusion criteria between 2008 and 2018, 33 received a conventional straight plate, while 29 were treated with a helical plate. The primary endpoint was iatrogenic radial nerve damage immediately after surgery with a follow-up of at least 3 months.

RESULTS

No case of radial nerve damage was reported in the helical group. In the control group, iatrogenic radial nerve damage occurred in two cases (6%), which was not statistically significant when comparing both groups (p = 0.18).

CONCLUSION

Manually twisting long PHILOS® plates is a safe procedure to avoid radial nerve lesion in humerus shaft fractures. Even though the group size did not allow a statistically relevant difference, we underline that only the helical group showed no iatrogenic radial lesion. This technique deserves further attention.

LEVEL OF EVIDENCE: Level 3, retrospective cohort study.

Для цитирования: Da Silva Tomas, Rummel Franziska, Knop Christian, Merkle Tobias. Comparing iatrogenic radial nerve lesions in humeral shaft fractures treated with helical or straight PHILOS plates: a 10-year retrospective cohort study of 62 cases.. Archives of orthopaedic and trauma surgery. 2020. DOI: 10.1007/s00402-020-03438-y.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.