DOI 10.1097/bot.0000000000000505

Медицинская библиотека · Journal of orthopaedic trauma · 2016

The Utility of the Tip-Apex Distance in Predicting Axial Migration and Cutout With the Trochanteric Fixation Nail System Helical Blade.

Flores Stephen A, Woolridge Adam, Caroom Cyrus, Jenkins Mark

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

To determine whether a tip-apex distance (TAD) <20 mm is associated with a higher rate of axial migration and perforation with the Trochanteric Fixation Nail (TFN) System helical blade implant.

DESIGN

Retrospective.

SETTING

Level I Trauma Center.

PARTICIPANTS

Four hundred forty-three patients surgically treated for proximal femur fractures were identified through a query of Current Procedural Terminology code 27245 from January 2009 to February 2013. A total of 258 patients treated with the TFN helical blade system were included in the study.

MAIN OUTCOME MEASURED: The association of axial migration and perforation with the measured TAD.

RESULTS

The overall rate of mechanical complications was 10.1%. The average TAD was 20.4 mm. Axial perforation occurred in 8 patients (3.4%). Axial migration up to subchondral bone without perforation occurred in 3 patients (1.1%). Only 1 fracture failed in varus (0.38%). There was a significant difference in the rates of combined axial migration and perforation with a TAD <20 mm (P = 0.03). Logistic regression model demonstrated increased odds for combined axial cutout and migration with TAD less than 20 (odds ratio = 1.15, P = 0.01).

CONCLUSIONS

A TAD <20 mm was associated with an increased frequency of axial migration and cutout with the TFN helical blade.

LEVEL OF EVIDENCE: Prognostic Level II. See Instructions for Authors for a complete description of levels of evidence.

Для цитирования: Flores Stephen A, Woolridge Adam, Caroom Cyrus, Jenkins Mark. The Utility of the Tip-Apex Distance in Predicting Axial Migration and Cutout With the Trochanteric Fixation Nail System Helical Blade.. Journal of orthopaedic trauma. 2016. DOI: 10.1097/bot.0000000000000505.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.