MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/0145561320980194

Медицинская библиотека · Ear, nose, & throat journal · 2020

Exhalation Delivery Systems for Application of Intranasal Corticosteroids.

Kovacs Alexander J, Adappa Nithin D, Kuan Edward C

СтатьяОбзорПеревод пока не подготовлен

Аннотация

BACKGROUND

Chronic rhinosinusitis (CRS) is a common sinonasal disorder which results in significant inflammation in the nasal cavity and paranasal sinuses. Topical nasal steroids play an important role in the treatment of CRS. Exhalation delivery system with fluticasone (EDS-FLU) utilizes a patient's forced exhalation to power the delivery of topical steroids to deeper areas of the nasal cavity and paranasal sinuses most affected by CRS. This review focuses on evidence surrounding the safety and efficacy of the EDS-FLU system.

METHODS

Literature search was conducted of articles investigating the safety and efficacy of EDS-FLU. Relevant efficacy and safety data were examined and summarized from the studies.

RESULTS

The efficacy and safety of EDS-FLU in CRS, both with and without polyps, has been established in open-label and placebo-controlled phase 3 trials. There was significant improvement in the cardinal symptoms of CRS and subjective patient-reported outcomes scores. Additionally, there was objective improvement in sinonasal inflammation as measured by polyp grade. Recent studies have also established significant improvement in health status and general quality of life following treatment using EDS-FLU. Emerging data have also examined patients who have previously had endoscopic sinus surgery and on appropriate medical therapy and noted improvement in polyp burden and overall Lund-Kennedy scores after using EDS-FLU.

CONCLUSION

Exhalation delivery system with fluticasone demonstrates significant results in both patient-oriented outcomes and objective measures of sinonasal inflammation in patients with CRS with and without polyps. Further research is needed to investigate the long-term outcomes of EDS-FLU and to compare the effects of EDS-FLU with ESS. Exhalation delivery system with fluticasone provides an additional effective treatment modality for patients suffering from CRS.

Для цитирования: Kovacs Alexander J, Adappa Nithin D, Kuan Edward C. Exhalation Delivery Systems for Application of Intranasal Corticosteroids.. Ear, nose, & throat journal. 2020. DOI: 10.1177/0145561320980194.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.