PURPOSE: The diagnosis and evaluation of dry eye require easy-to-use, precise, and consistent tools in clinical setting. Matrix metalloproteinase 9 (MMP-9) has been proven to be a reliable indicator of dry eye inflammation. The aim of this study is to establish an Eu-time resolved fluorescence immunochromatography (Eu-TRFICO) method for quantitative detection of MMP-9 in human tear based upon widely used Schirmer strips.

METHODS

The Eu-TRFICO method for Schirmer strip-based tear MMP-9 measurements were optimized and assembled. The sensitivity, repeatability and homogeneity were evaluated using MMP-9 standard dilutions. The diagnostic and treatment monitoring performance were evaluated in both dry eye patients and normal subjects.

RESULTS

The standard curve equation was y = 0.0037 + 8.0692/[1+ (x/188.322)-0.8972] (R2 = 0.99998), and the sensitivity was 0.25 ng/mL. The Schirmer strip-based MMP-9 measurements showed acceptable repeatability and homogeneity with different saturation length in both low and high standard solutions. A total of 162 participants (162 eyes) were enrolled in this study, including 41 normal and 121 dry eye subjects. This method exhibited a sensitivity of 74.17 % and specificity of 77.5 % for dry eye diagnosis, with an AUC value of 0.8275, and cutoff value of 150.67 ng/mL, using normal subjects as negative control. The tear MMP-9 concentrations monitored with this method correlated well with the therapeutic response in dry eye patients.

CONCLUSIONS

This study developed Eu-TRFICO Schirmer strips with high sensitivity, specificity, precision, and satisfactory clinical testing performance, which provides a convenient and quantitative option for clinical testing of tear MMP-9 in dry eye patients.

Для цитирования: Chen Di, Li Wubi, Yang Shan, Song Hang, Di Yu, Zhong Weixing, Zhang Miao, Long Qin, Li Ying, Zhao Chan. A novel Schirmer strip-based tear matrix metalloproteinase measurement in dry eye evaluation.. The ocular surface. 2025. DOI: 10.1016/j.jtos.2025.01.004.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.