Assessment of colon motility using simultaneous manometric and functional cine-MRI analysis: preliminary results.

Kirchhoff Sonja, Nicolaus Mathias, Schirra Jörg, Reiser Maximilian F, Göke Burkhard, Lienemann Andreas

Оценочное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: Gastrointestinal functional disorders are common symptoms. The evaluation of underlying colonic motility dysfunction is difficult due to lacking adequate examination techniques. Recently cine-magnetic resonance imaging (MRI) was introduced as imaging technique for visualizing colon motility. However, the correlation of MR-visible colonic-movements and real intraluminal movements was not demonstrated yet. Therefore, this feasibility study's purpose was to stimulate high amplitude propagated pressure waves (HAPPWs) by bisacodyl application under manometric control and to simultaneously identify them with cine-MRI.

MATERIALS AND

METHODS

Colonoscopically, a water-perfused 8-lumen-probe was placed in descending colon. Intraluminal pressure was recorded over time. After 90 min equilibration phase, MR exam at rest (HASTE-sequence, 1.5Tesla-Avanto(®), Siemens-Medical-Solutions) was performed. Consecutively, 10 mg bisacodyl were instilled via colonic probe to induce HAPPWs. Cine-MRI and manometry were performed simultaneously over 24 min. HAPPWs were defined as pressure waves with amplitude >50 mmHg and propagation over min. three side-holes. MRI was analyzed for corresponding luminal changes of the referring colonic segment propagated aborally.

RESULTS

Ten healthy volunteers (age:19-62 years, 4 females, 6 males) were enrolled. Manometry identified 11 HAPPWs, most 9-16 min post-stimulation. All HAPPWs were identified on MRI with corresponding luminal changes (100% sensitivity).

CONCLUSIONS

In accordance with our study group's previous publications, these results show that cine-MRI allows not only for reliable HAPPWs' visualization using pharmalogical stimuli, but visualized colonic movements have 100% correlation to intraluminal pressure changes in manometry (gold-standard). This may be a first step to introduce cine-MRI for non-invasive colon motility assessment in patients with functional gastro-intestinal disorders.

Для цитирования: Kirchhoff Sonja, Nicolaus Mathias, Schirra Jörg, Reiser Maximilian F, Göke Burkhard, Lienemann Andreas. Assessment of colon motility using simultaneous manometric and functional cine-MRI analysis: preliminary results.. Abdominal imaging. 2011. DOI: 10.1007/s00261-010-9599-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.