Physiological responses to cisplatin using a mouse hypersensitivity model.

Lehmann David M, Williams Wanda C

СтатьяПеревод пока не подготовлен

Аннотация

Background

The physiological mechanisms underlying the development of respiratory hypersensitivity to cisplatin (CDDP) are not well-understood. It has been suggested that these reactions are likely the result of type I hypersensitivity, but other explanations are plausible and the potential for CDDP to induce type I hypersensitivity responses has not been directly evaluated in an animal model. Objectives and

Methods

To investigate CDDP hypersensitivity, mice were topically sensitized through application of CDDP before being challenged by oropharyngeal aspiration (OPA) with CDDP. Before and immediately after OPA challenge, pulmonary responses were assessed using whole body plethysmography (WBP).

Results

CDDP did not induce an immediate response or alter the respiratory rate in sensitized mice. Two days later, baseline enhanced pause (Penh) values were significantly elevated (p < 0.05) in mice challenged with CDDP. When challenged with methacholine (Mch) aerosol, Penh values were significantly elevated (p < 0.05) in sensitized mice and respiratory rate was reduced (p < 0.05). Lymph node cell counts and immunoglobulin E levels also indicated successful sensitization to CDDP. Irrespective of the sensitization state of the mice, the number of neutrophils increased significantly in bronchoalveolar lavage fluid (BALF) following CDDP challenge. BALF from sensitized mice also contained 2.46 (±0.8) × 104 eosinophils compared to less than 0.48 (±0.2) × 104 cells in non-sensitized mice (p < 0.05).

Conclusions

The results from this study indicate that dermal exposure to CDDP induces immunological changes consistent with type I hypersensitivity and that a single respiratory challenge is enough to trigger pulmonary responses in dermally sensitized mice. These data provide previously unknown insights into the mechanisms of CDDP hypersensitivity.

Для цитирования: Lehmann David M, Williams Wanda C. Physiological responses to cisplatin using a mouse hypersensitivity model.. Inhalation toxicology. 2020. DOI: 10.1080/08958378.2020.1737762.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.