MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4269/ajtmh.2010.09-0566

Медицинская библиотека · The American journal of tropical medicine and hygiene · 2010

Optimizing tuberculosis testing for basic laboratories.

Ramos Eric, Schumacher Samuel G, Siedner Mark, Herrera Beatriz, Quino Willi, Alvarado Jessica, Montoya Rosario, Grandjean Louis, Martin Laura, Sherman Jonathan M, Gilman Robert H, Evans Carlton A

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Optimal tuberculosis testing usually involves sputum centrifugation followed by broth culture. However, centrifuges are biohazardous and scarce in the resource-limited settings where most tuberculosis occurs. To optimize tuberculosis testing for these settings, centrifugation of 111 decontaminated sputum samples was compared with syringe-aspiration through polycarbonate membrane-filters that were then cultured in broth. To reduce the workload of repeated microscopic screening of broth cultures for tuberculosis growth, the colorimetric redox indicator 2,3-diphenyl-5-(2-thienyl) tetrazolium chloride was added to the broth, which enabled naked-eye detection of culture positivity. This combination of filtration and colorimetric growth-detection gave similar results to sputum centrifugation followed by culture microscopy regarding mean colony counts (43 versus 48; P = 0.6), contamination rates (0.9% versus 1.8%; P = 0.3), and sensitivity (94% versus 95%; P = 0.7), suggesting equivalency of the two methods. By obviating centrifugation and repeated microscopic screening of cultures, this approach may constitute a more appropriate technology for rapid and sensitive tuberculosis diagnosis in basic laboratories.

Для цитирования: Ramos Eric, Schumacher Samuel G, Siedner Mark, Herrera Beatriz, Quino Willi, Alvarado Jessica, Montoya Rosario, Grandjean Louis, Martin Laura, Sherman Jonathan M, Gilman Robert H, Evans Carlton A. Optimizing tuberculosis testing for basic laboratories.. The American journal of tropical medicine and hygiene. 2010. DOI: 10.4269/ajtmh.2010.09-0566.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.