MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1088/1752-7163/abde95

Медицинская библиотека · Journal of breath research · 2021

Monitoring of endogenous nitric oxide exhaled by pig lungs during ex-vivo lung perfusion.

Chollier Thibaut, Richard Lucile, Romanini Daniele, Brouta Angélique, Martin Jean-Luc, Moro Cécile, Briot Raphaël, Ventrillard Irène

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

In the context of organ shortage for transplantation, new criteria for better organ evaluation should be investigated. Ex-vivo lung perfusion (EVLP) allows extra-corporal lung re-conditioning and evaluation, under controlled parameters of the organ reperfusion and mechanical ventilation. This work reports on the interest of exhaled gas analysis during the EVLP procedure. After a 1 h cold ischemia, the endogenous gas production by an isolated lung of nitric oxide and carbon monoxide is simultaneously monitored in real time. The exhaled gas is analysed with two very sensitive and selective laser spectrometers developed upon the technique of optical-feedback cavity-enhanced absorption spectroscopy. Exhaled gas concentration measured for an ex-vivo lung is compared to the corresponding production by the whole living pig, measured before euthanasia. On-line measurements of the fraction of nitric oxide in exhaled gas (FENO) in isolated lungs are reported here for the first time, allowing to resolve the respiratory cycles. In this study, performed on 9 animals, FENO by isolated lungs range from 3.3 to 10.6 ppb with a median value of 4.4 ppb. Pairing ex-vivo lung and pig measurements allows to demonstrate a systematic increase of FENO in the ex-vivo lung as compared to the living animal, by a factor of 3 ± 1.2. Measurements of the fraction of carbon monoxide in exhaled gas (FECO) confirm levels recorded during previous studies driven to evaluate FECO as a potential marker of ischemia reperfusion injuries. FECO production by ex-vivo lungs ranges from 0.31 to 2.3 ppm with a median value of 0.8 ppm. As expected, these FECO values are lower than the production by the corresponding whole pig body, by a factor of 6.9 ± 2.7.

Для цитирования: Chollier Thibaut, Richard Lucile, Romanini Daniele, Brouta Angélique, Martin Jean-Luc, Moro Cécile, Briot Raphaël, Ventrillard Irène. Monitoring of endogenous nitric oxide exhaled by pig lungs during ex-vivo lung perfusion.. Journal of breath research. 2021. DOI: 10.1088/1752-7163/abde95.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.