MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/bmc.4853

Медицинская библиотека · Biomedical chromatography : BMC · 2020

Development of a precise quantitative method for monitoring sirolimus in whole blood using LC/ESI-MS/MS.

Shigeta Kensuke, Kikuchi Masafumi, Tanaka Masaki, Takasaki Shinya, Oishi Hisashi, Sado Tetsu, Matsuda Yasushi, Noda Masafumi, Okada Yoshinori, Mano Nariyasu, Yamaguchi Hiroaki

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

Sirolimus is used on patients after solid organ transplantation and on lymphangioleiomyomatosis (LAM) patients, and therapeutic drug monitoring is required in clinical practice. We have previously reported an accurate method for quantitative determination of sirolimus, but its sample preparation step was complicated. In this study, we developed a modified liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) method for sirolimus quantification. A supported liquid extraction cartridge was used to purify sirolimus from whole blood and ion suppression was mostly prevented. The validation results met the acceptance criteria. This method was compared with the antigen conjugated magnetic immunoassay (ACMIA) and our previously reported method, using whole blood samples from LAM patients. Comparison of the Bland-Altman plots of the currently developed method and the previous method revealed no significant difference between the two methods (mean bias, -2.02%; 95% CI, -7.81-3.78). The values obtained using ACMIA were significantly higher than those obtained using the current method by 13.87% (95% CI, 6.49-21.25) owing to cross-reactivity. The degrees of cross reactivities in LAM patients and in organ transplant patients were similar, and our LC/ESI-MS/MS method precisely measured the blood concentrations of sirolimus.

Для цитирования: Shigeta Kensuke, Kikuchi Masafumi, Tanaka Masaki, Takasaki Shinya, Oishi Hisashi, Sado Tetsu, Matsuda Yasushi, Noda Masafumi, Okada Yoshinori, Mano Nariyasu, Yamaguchi Hiroaki. Development of a precise quantitative method for monitoring sirolimus in whole blood using LC/ESI-MS/MS.. Biomedical chromatography : BMC. 2020. DOI: 10.1002/bmc.4853.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.