DOI 10.1177/0391398819876293

Медицинская библиотека · The International journal of artificial organs · 2019

Recurrent pump thrombosis is common after axial continuous-flow left ventricular assist device exchange.

Urban Marian, Um John, Moulton Michael, Stoller Douglas, Zolty Ronald, Lowes Brian, Macdonald Collin, McCain Natalia, Siddique Aleem

СтатьяПеревод пока не подготовлен

Аннотация

In selected patients with left ventricular assist device-associated infection or malfunction, pump exchange may become necessary after conservative treatment options fail and heart transplantation is not readily available. We examined the survival and complication rate in patients (⩾19 years of age) who underwent HeartMate II to HeartMate II exchange at our institution from 1 January 2010 to 28 February 2018. Clinical outcomes were analyzed and compared for patients who underwent exchange for pump thrombosis (14 patients), breach of driveline integrity (5 patients), and device-associated infection (2 patients). There were no differences in 30-day mortality (p = 0.58), need for temporary renal replacement therapy (p = 0.58), right ventricular mechanical support (p = 0.11), and postoperative stroke (p = 0.80) among groups. Survival at 1 year was 90% ± 7% for the whole cohort and 85% ± 10% for those who underwent exchange for pump thrombosis. In patients exchanged for device thrombosis, freedom from re-thrombosis and survival free from pump re-thrombosis at 1 year were 49% ± 16% and 42% ± 15%, respectively. No association of demographic and clinical variables with the risk of recurrent pump thrombosis after the first exchange was identified. Survival after left ventricular assist device exchange compares well with published results after primary left ventricular assist device implantation. However, recurrence of thrombosis was common among patients who required a left ventricular assist device exchange due to pump thrombosis. In this sub-group, consideration should be given to alternative strategies to improve the outcomes.

Для цитирования: Urban Marian, Um John, Moulton Michael, Stoller Douglas, Zolty Ronald, Lowes Brian, Macdonald Collin, McCain Natalia, Siddique Aleem. Recurrent pump thrombosis is common after axial continuous-flow left ventricular assist device exchange.. The International journal of artificial organs. 2019. DOI: 10.1177/0391398819876293.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.