MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3389/fped.2026.1902579

Медицинская библиотека · Frontiers in pediatrics · 2026

A stabilization device significantly improves measurement reliability and efficiency of Graf ultrasonography for developmental dysplasia of the hip: a retrospective cohort study.

Lan Yehui, Tang Liyu, Jin Miao, Du Bin, Yan Jianfei, Wu Quanzhou, Lu Chenying, Huang Yanhua, Chen Zhihui

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

To compare the measurement reliability, procedural efficiency, and infant stress responses between device-assisted and manual restraint approaches in Graf hip ultrasonography for developmental dysplasia of the hip (DDH) screening.

METHODS

In this retrospective cohort study, 238 infants (aged 0-6 months) underwent consecutive hip ultrasound examinations using both a Graf stabilization device and manual restraint during the same visit. Each examination included triple measurements of α and β angles by a single experienced sonographer. Primary outcomes included angle measurements and Graf classification. Examination time and infant crying incidence were also recorded. Intra-observer reliability for repeated measurements within each technique and inter-technique agreement between the two methods were evaluated separately using intraclass correlation coefficients (ICC) and Cohen's kappa.

RESULTS

No significant differences were observed in α angle (67.00° vs. 67.50°, P = 0.313), β angle (71.00° vs. 69.00°, P = 0.179), or Graf classification distribution (P = 0.832) between device-assisted and manual methods. However, the device-assisted approach showed significantly shorter examination time (P < 0.001) and a 13.5-fold reduction in crying incidence (0.84% vs. 11.34%, P < 0.001). Intra-observer reliability was excellent with device assistance (α angle: ICC = 0.95, β angle: ICC = 0.90) but poor with manual restraint (α angle: ICC = 0.49, β angle: ICC = 0.23). Inter-technique agreement was moderate for α angle (ICC = 0.71) and substantial for Graf classification (κ = 0.66), but poor with β angle (ICC = 0.36).

CONCLUSION

The use of a stabilization device in Graf hip ultrasonography significantly improves measurement reliability and may enhance examination efficiency and infant comfort without altering diagnostic outcomes, supporting its integration into high-volume DDH screening programs.

Для цитирования: Lan Yehui, Tang Liyu, Jin Miao, Du Bin, Yan Jianfei, Wu Quanzhou, Lu Chenying, Huang Yanhua, Chen Zhihui. A stabilization device significantly improves measurement reliability and efficiency of Graf ultrasonography for developmental dysplasia of the hip: a retrospective cohort study.. Frontiers in pediatrics. 2026. DOI: 10.3389/fped.2026.1902579.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.