Journal of imaging informatics in medicine · 2026
Multimodal Large Language Models for Breast Ultrasound Report Auditing: Workflow-Error Detection, False-Positive Burden, and Limits of Key-Image Interpretation.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Zou Mi, Xiao Mengsu, Zhu Qingli, Zhang Jing, Li Jianchu, Lv Ke
Аннотация
Large language models (LLMs) are increasingly being evaluated for radiology reporting. However, the incremental value of adding report-embedded key images to report text for breast ultrasound report auditing remains unclear. This retrospective study included 818 breast ultrasound examinations with pathology- or follow-up-based reference standards. A workflow-error-enriched 300-report subset was constructed, comprising 240 reports with 329 inserted errors and 60 error-free reports. GPT-5.5 and Gemini 3.1 Pro Preview were evaluated under two input settings: report text alone and multimodal input; the latter additionally included report-embedded key images. A physician reader provided a human benchmark. In the full cohort, GPT-5.5 was evaluated with key-image input versus physician-interpreted findings input for malignancy and BI-RADS risk classification. Multimodal input increased report-level sensitivity from 77.5% to 89.6% for GPT-5.5 and from 86.2% to 96.2% for Gemini. Error-level recall increased from 63.2% to 75.4% and from 72.0% to 83.6%, respectively. Gains were concentrated in errors involving image-displayed cues. Gemini with multimodal input produced false-positive outputs in 18/60 error-free reports and 12/240 error-enriched reports, mainly from body-marker misinterpretation. The physician reader achieved 91.7% report-level sensitivity and 83.0% error-level recall without false positives. In the full cohort, key-image input underperformed physician-interpreted findings input for malignancy classification (AUC, 0.879 vs 0.971) and BI-RADS risk classification (AUC, 0.887 vs 0.984). Multimodal input improved LLM-based breast ultrasound workflow-error detection, with gains concentrated in errors involving image-displayed cues. However, model-specific overcalling and the inferior performance of key-image input compared with physician-interpreted findings warrant caution in clinical implementation.