MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1309/2pmf-3hk9-v8tt-vfun

Медицинская библиотека · American journal of clinical pathology · 2000

Detection of von Willebrand disorder and identification of qualitative von Willebrand factor defects. Direct comparison of commercial ELISA-based von Willebrand factor activity options.

Favaloro E J

Сравнительное исследованиеОценочное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

Two von Willebrand factor (vWF):collagen binding (activity) assay (CBA) kit methods are commercially available. A monoclonal antibody (MAB)-based enzyme-linked immunosorbent assay (ELISA) system reported to correlate with a standard vWF:ristocetin cofactor (RCof) assay is also commercially available. It is marketed as a vWF:Activity assay and is available in 2 assay version formats. In the present study, these 4 vWF-activity options were compared directly with in-house vWF:CBA ELISAs for their ability to detect von Willebrand disease (vWD) and identify qualitative vWF defects. The 2 MAB-based systems detected vWD but could not specifically identify qualitative vWF defects, although the recently modified Mark II kit was more effective for the latter compared with the original Mark I kit. All vWF:CBA methods, including in-house and commercial, also effectively detected vWD but differed in their ability to identify qualitative vWF defects. Effectiveness was highest using the in-house reference vWF:CBA (using a type I/III collagen mix product from equine tendon), the Gradipore vWF:CBA (also uses equine tendon-derived collagen), or the in-house vWF:CBA methods using type III human collagen at a relatively low concentration (1 or 3 micrograms/mL, without covalent linkage). The IMMUNO vWF:CBA seemed to be the least effective among the vWF:CBA methods for detection of qualitative vWF defects.

Для цитирования: Favaloro E J. Detection of von Willebrand disorder and identification of qualitative von Willebrand factor defects. Direct comparison of commercial ELISA-based von Willebrand factor activity options.. American journal of clinical pathology. 2000. DOI: 10.1309/2pmf-3hk9-v8tt-vfun.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.