DOI 10.1002/nau.23147

Медицинская библиотека · Neurourology and urodynamics · 2016

Can filling phase urodynamic parameters predict the success of the bulbar artificial urinary sphincter in treating post-prostatectomy incontinence?

Solomon Eskinder, Veeratterapillay Rajan, Malde Sachin, Harding Christopher, Greenwell Tamsin Jillian

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To evaluate whether filling phase urodynamic parameters can predict the success of the artificial urinary sphincter (AUS) in treating post-prostatectomy incontinence (PPI).

MATERIALS AND

METHODS

We reviewed the pre-AUS urodynamics of 99 patients with PPI at two tertiary referral centers. We documented the peak DO pressure (Pdet ), capacity, and compliance (C). We defined success as patient-reported continence or only using one safety pad. Patients' perception of improvement was assessed using the PGI-I score.

RESULTS

Sixty-eight percent (n = 68) of patients had a successful outcome. The mean compliance for the "success" and "failure" group was 112.3 mL/cmH2 O (±119.7) and 34.1 mL/cmH2 O (±36.2), respectively. Fifty-five percent (17/31) of patients in the "failure" group demonstrated DO(Pdet  = 36.2 ± 18.2 cmH2 O) compared to 18% (12/68) in the success group. The differences between the two groups in Pdet and compliance were statistically significant (all P < 0.01). There was, however, no statistical difference between the mean cystometric capacities of patients in the two outcome groups. Thirteen out of 18 (72%) patients who had radiotherapy had a poor outcome ("success" group only 15% [9/59]). These results were used to develop a nomogram for the probability of AUS success. A good inverse correlation (r = -0.65) was demonstrated between the probability of AUS success as deduced from the nomogram and PGI-I score post-AUS implantation

CONCLUSION

Compliance and Pdet are predictors of outcome following AUS implantation for PPI. We have developed and internally validated a nomogram that may be used to determine an individualized likelihood of AUS success. This nomogram may be used as a counseling tool to objectively set realistic expectations of continence post-AUS implantation.

Для цитирования: Solomon Eskinder, Veeratterapillay Rajan, Malde Sachin, Harding Christopher, Greenwell Tamsin Jillian. Can filling phase urodynamic parameters predict the success of the bulbar artificial urinary sphincter in treating post-prostatectomy incontinence?. Neurourology and urodynamics. 2016. DOI: 10.1002/nau.23147.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.