BACKGROUND

Leadless cardiac pacemaker (LCP) requires large-caliber venous sheaths for device placement. Sheath sizes for these procedures vary from 18- to 23-French (F). The most common complications are hematomas, pseudoaneurysms, and arteriovenous fistulas. Complete and secure closure of the venous access is an important step at the end of such a procedure.

METHODS

We performed a retrospective analysis of all patients who had undergone LCP implantation at our institution. Patients and procedural characteristics as well as groin complications at 30 days and 3 months were evaluated. After sheath removal venous access sites were closed performing a so-called "purse-string" suture (PSS).

RESULTS

Seventy-seven patients received an LCP at our institution. In 27 (35%) of these patients a heparin bolus was given at the beginning of the procedure. Anticoagulation therapy with phenprocoumon was present in 32 (40%) of patients. In 76 (98.7%) patients, the LCP was implanted without complications. In one (1.3%) patient a perforation occurred during implantation, which required surgical intervention. Access site complications occurred in three (3.9%) patients, two (2.6%) groin hematomas, and one (1.3%) arteriovenous fistula. The hematomas disappeared completely after 3 weeks, and the fistula was not detectable by ultrasound anymore after 4 weeks.

CONCLUSION

Use of subcutaneous absorbable double PSS closure after removal of large-caliber venous sheaths is a safe technique to achieve immediate postprocedural hemostasis. Especially for sheath sizes with an inner diameter of 23F, this technique creates a very secure and also cosmetically appealing closure.

Для цитирования: Kypta Alexander, Blessberger Hermann, Lichtenauer Michael, Kammler Juergen, Lambert Thomas, Kellermair Joerg, Nahler Alexander, Kiblboeck Daniel, Schwarz Stefan, Steinwender Clemens. Subcutaneous Double "Purse String Suture"-A Safe Method for Femoral Vein Access Site Closure after Leadless Pacemaker Implantation.. Pacing and clinical electrophysiology : PACE. 2016. DOI: 10.1111/pace.12867.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.