MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/s0022-5223(03)01317-5

Медицинская библиотека · The Journal of thoracic and cardiovascular surgery · 2004

Experimental study of a new tracheal prosthesis: pored Dacron tube.

Tsukada Hisashi, Osada Hiroaki

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

This study was designed to evaluate how various sizes and densities of pores in Dacron tubing might enhance its utility as a tracheal prosthesis.

METHODS

A vascular prosthesis made of knitted external velour polyester was prepared for pore formation with a laser. The first set compared different pore sizes (300, 500, and 700 microm) and pore densities (25/cm(2) or 100/cm(2)). Grafts were reinforced with an externally heat-sealed silicone ring. The second set tested grafts with a pore density of 64/cm(2) and a pore size of 500 microm internally reinforced with a stainless-steel spiral stent. In all experiments, a canine mediastinal trachea 10 cartilage rings in length was resected, and the prosthesis was then implanted with an omental flap.

RESULTS

Lower pore size and density (300 microm, 25 pores/cm(2)) led to essentially no tissue ingrowth. Larger pore size (700 microm) and low density (25 pores/cm(2)) led to rapid and excessive ingrowth of granulation. Midrange pore size (500 microm) and high density (100 pores/cm(2)) invited steady tissue ingrowth, but marked luminal stenosis eventually developed. Stent-reinforced prostheses with 500-microm pores at 64 pores/cm(2), as used in the second set, maintained an average patency rate of 60% or more (range, 20%-100%) at least 12 months after implantation.

CONCLUSION

Our data show that porosity is a key factor for tissue growth through our Dacron tracheal prostheses. This artificial trachea model has led to long-term survivors up to 27 months after the operation and seems promising as a basic model for clinical tracheal repair.

Для цитирования: Tsukada Hisashi, Osada Hiroaki. Experimental study of a new tracheal prosthesis: pored Dacron tube.. The Journal of thoracic and cardiovascular surgery. 2004. DOI: 10.1016/s0022-5223(03)01317-5.