MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/jbm.a.10462

Медицинская библиотека · Journal of biomedical materials research. Part A · 2003

Coaxial double-tubular compliant arterial graft prosthesis: time-dependent morphogenesis and compliance changes after implantation.

Sonoda Hiromichi, Takamizawa Keiichi, Nakayama Yasuhide, Yasui Hisataka, Matsuda Takehisa

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

In order to reduce the compliance mismatch between the native artery and the artificial graft, we have developed a coaxial double-tubular compliant graft, using multiply micropored segmented polyurethane (SPU) thin films, which mimics the relationship between the intraluminal pressure and vessel internal diameter (P-D) of the native artery (termed "J" curve). The graft was coaxially assembled by inserting a high-compliance inner tube with a heparin-immobilized photocured gelatin coating layer into a low-compliance outer tube with a photocured hydrophilic polymer coating layer. Twenty-eight coaxial double-tubular compliant grafts were implanted into the canine common carotid arteries in an end-to-end fashion for up to 12 months. The overall patency rate was 86% (24/28), and neither rupture nor aneurysmal formation was observed. A neoarterial wall was formed via transanastomotic and transmural tissue ingrowth, resulting in neoarterial tissue formation on the luminal surface and into the intertubular space of the double-tubular graft, accompanied by mainly myofibroblasts and inflammatory cells in the early stage and endothelialization and collagen-rich extracellular matrices in the late stage of implantation. Surrounding-tissue adhesion with the outer tube was prevented by the hydrophilic polymer coating. Although the J curve of the implanted prototype model was preserved 1 month after implantation, the impaired J curves were observed because of tissue ingrowth and tissue adhesion between the outer surface of the inner tube and the surrounding tissues 3 and 6 months after implantation. At 12 months after implantation, however, the implanted coaxial double-tubular graft exhibited high compliance due to biodegradation of the SPU films.

Для цитирования: Sonoda Hiromichi, Takamizawa Keiichi, Nakayama Yasuhide, Yasui Hisataka, Matsuda Takehisa. Coaxial double-tubular compliant arterial graft prosthesis: time-dependent morphogenesis and compliance changes after implantation.. Journal of biomedical materials research. Part A. 2003. DOI: 10.1002/jbm.a.10462.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.