Exploring the Relationships Between Clinical Examination Findings, Subjective Reported Symptoms and Objective Nasal Patency Measures in Nasal Obstruction: A Baseline NAIROS Sub-Study Analysis.
Аннотация
BACKGROUND
The role of objective nasal airflow measures using peak nasal inspiratory flow (PNIF) and rhinospirometry in supporting clinical examination findings when offering patients septoplasty remain undefined.
OBJECTIVE
To explore the baseline relationships between clinical examination findings, subjective reported symptoms and objective nasal patency measures in nasal obstruction.
METHODS
This is a sub-study of the NAIROS trial. Participants with nasal obstruction secondary to septal deviation were included in this NAIROS sub-study. The side of septal deviation, enlargement of inferior turbinate (IT), the need for IT reduction if septoplasty was being performed, the area of septum deflecting into the airway and observer rated airway block (ORAB-arbitrarily divided by <50% and >50% blockage) were assessed by clinicians. The subjective score of nasal obstruction was assessed using the Double Ordinal Assessed Subjective Scale (DOASS). Objective nasal patency measures (e.g., nasal partitioning ratio, [NPR] and PNIF) were measured using PNIF and rhinospirometry.
RESULTS
The mean NPR for left-sided, both-sided and right-sided septal deviation was -0.35, -0.02 and 0.51, respectively (p < 0.001). There was very weak correlation between the requirement for IT reduction and PNIF change (0.13, p < 0.01). There was no difference in mean PNIF (94 L/min vs. 93 L/min) and mean DOASS (0.33 vs. 0.38) for participants with ORAB rated <50% and >50%. The mean NPR for participants with ORAB >50% was higher than for those with ORAB <50% (0.51 vs. 0.41, p = 0.002). There was strong correlation between the DOASS and NPR (+0.737, p < 0.001). The mean DOASS score for right-sided, both-sided and left-sided septal deviation was 0.32, 0.05 and -0.29, respectively (p < 0.001).
CONCLUSION
This study identified strong relationships between the clinician rated side of septal deflection, the patient reported DOASS and the objective NPR measurements. NPR and the clinician rated degree of airway blockage were concordant.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.