Noninvasive Ventilation or CPAP in the Initial Treatment Phase of Small Infants With Respiratory Failure.
Аннотация
Background
Respiratory failure in infants is a common reason for admission to the pediatric ICU (PICU). Although high-flow nasal cannula (HFNC) is the preferred first-line treatment at our institution, some infants require CPAP or noninvasive ventilation (NIV). Here we report our experience using CPAP/NIV in infants <10 kg.
Methods
We conducted a retrospective review of infants <10 kg treated with CPAP/NIV in our PICUs between July 2017-May 2021 in the initial phase of treatment. Demographic, support type and settings, vital signs, pulse oximetry, and intubation data were extracted from the electronic health record. We compared subjects successfully treated with CPAP/NIV with those who required intubation.
Results
We studied 62 subjects with median (interquartile range) age 96 [6.5-308] d and weight 4.5 (3.4-6.6) kg. Of these, 22 (35%) required intubation. There were no significant differences in demographics, medical history, primary interface, pre-CPAP/NIV support, and device used to deliver CPAP/NIV. HFNC was used in 57 (92%) subjects before escalation to CPAP/NIV. Subjects who failed CPAP/NIV were less likely to have bronchiolitis (27% vs 60%, P = .040), less likely to be discharged from the hospital to home (68% vs 93%, P = .02), had a longer median hospital length of stay (LOS) (26.9 [21-50.5] d vs 10.4 [5.6-28.4] d, P = .002), and longer median ICU LOS (14.6 [7.9-25.2] d vs 5.8 [3.8-12.4] d, P = .004). Initial vital signs and FIO2 were similar, but SpO2 was lower and FIO2 higher at 6 h and 12 h after support initiation for subjects who failed CPAP/NIV. Initial CPAP/NIV settings were similar, but subjects who failed CPAP/NIV had higher maximum and final inspiratory/expiratory pressure.
Conclusions
Most infants who failed initial HFNC support were successfully managed without intubation using NIV or CPAP. Bronchiolitis was associated with a lower rate of CPAP/NIV failure, whereas lower SpO2 and higher FIO2 levels were associated with higher rates of intubation.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.