Validation of three weight gain-based algorithms as a screening tool to detect retinopathy of prematurity: A multicenter study.
Аннотация
PURPOSE: Screening guidelines for retinopathy of prematurity (ROP) are updated frequently to help clinicians identify infants at risk of type 1 ROP. This study aims to evaluate the accuracy of three different predictive algorithms-WINROP, ROPScore, and CO-ROP-in detecting ROP in preterm infants in a developing country.
METHODS
This retrospective study was conducted on 386 preterm infants from two centers between 2015 and 2021. Neonates with gestational age ≤30 weeks and/or birth weight ≤1500 g who underwent ROP screening were included.
RESULTS
One hundred twenty-three neonates (31.9%) developed ROP. The sensitivity to identify type 1 ROP was as follows: WINROP, 100%; ROPScore, 100%; and CO-ROP, 92.3%. The specificity was 28% for WINROP, 1.4% for ROPScore, and 19.3% for CO-ROP. CO-ROP missed two neonates with type 1 ROP. WINROP provided the best performance for type 1 ROP with an area under the curve score at 0.61.
CONCLUSION
The sensitivity was at 100% for WINROP and ROPScore for type 1 ROP; however, specificity was quite low for both algorithms. Highly specific algorithms tailored to our population may serve as a useful adjunctive tool to detect preterm infants at risk of sight-threatening ROP.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.