DOI 10.1186/s12890-022-02012-z
Multiple breath washout lung function reveals ventilation inhomogeneity unresponsive to mechanical assisted cough in patients with neuromuscular disease.
Аннотация
BACKGROUND
Respiratory involvement defines the clinical outcome of neuromuscular diseases (NMD). The lung clearance index (LCI) is a marker of lung ventilation inhomogeneity and indicates small airway disease. It is determined by mulitple breath washout lung function (MBW). The merit of LCI is undisputed for primary lung diseases like cystic fibrosis, but its role in NMD is unclear.
METHODS
We investigated the role of MBW in patients with NMD and the effect of two different tracer gases and cough assist devices on the LCI. Patients and controls performed MBW with nitrogen (N2) and sulfur hexafluoride (SF6), whereas the latter analysis was repeated after the use of a cough assist device in the NMD group. LCI was compared to forced vital capacity (FVC) and peak cough flow (PCF).
RESULTS
24 NMD patients (12 Duchenne Muscular Dystrophy, 8 Spinal Muscular Atrophy, 4 other NMDs) and 15 healthy controls were enrolled. In the NMD group, overall LCI N2 was higher than LCI SF6 (9.67 ± 1.56 vs. 8.71 ± 1.47; mean ± SD; p < 0.033). In controls, LCI N2 did not differ significantly from LCI SF6 (7.03 ± 0.37 vs. 7.05 ± 0.67; p = 0.882). Both LCI N2 and LCI SF6 were significantly higher in NMD patients as in controls (9.67 ± 1.56 vs. 7.03 ± 0.37, p < 0.001, and 8.71 ± 1.478.65 vs. 7.05 ± 0.67, p < 0.001). In the NMD group, both LCI N2 and LCI SF6 showed a negative correlation to FVC (r = - 0.525; p = 0.008 and r = - 0.526; p = 0.008, respectively) and PCF (r = - 0.590; p = 0.002 and r = - 0.641; p = 0.001, respectively). LCI N2 and LCI SF6 correlated well in the NMD group. LCI SF6 did not change significantly after the use of the cough assist in NMD patients (n = 22; 8.65 ± 1.52 pre vs. 8.79 ± 2.03 post, p = 0.667).
CONCLUSION
Lung involvement of patients with neuromuscular diseases goes beyond weakness of respiratory muscles. MBW with both N2 and SF6 is suitable to detect ventilation inhomogeneity in NMD patients with respiratory impairment. Cough assist devices with low to moderate pressure levels do not immediately improve the LCI.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.