MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/ina.12612

Медицинская библиотека · Indoor air · 2019

Measuring the administered dose of particles on the facial mucosa of a realistic human model.

Duan Mengjie, Liu Li, Da Guillaume, Géhin Evelyne, Nielsen Peter V, Weinreich Ulla M, Lin Borong, Wang Yi, Zhang Ting, Sun Wei

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Exposure to particulate contaminants can cause serious adverse health effects. Deposition on the facial mucosa is an important path of exposure, but it is difficult to conduct direct dose measurement on real human subjects. In this study, we propose an in vitro method to assess the administered doses of micron-sized particles on the eyes and lips in which computed tomographic scanning and three-dimensional printing were used to create a model that includes a face, oropharynx, trachea, the first five generations of bronchi, and lung volume. This realistic model of a face and airway was exposed to monodispersed fluorescent particles released from an incoming jet. The administered dose of particles deposited upon the eyes and lips, as quantified by fluorescence intensity, was determined via a standard wiping protocol. The results show that, in this scenario, the administered doses normalized by source were 2.15%, 1.02%, 0.88%, 2.13%, and 1.55% for 0.6-, 1.0-, 2.0-, 3.0-, and 5.0-µm particles, respectively. The administered dose of large particles on the mucosa within a given exposure time has great significance. Moreover, the lips suffer a much greater risk of exposure than the eyes and account for more than 80% of total facial mucosa deposition. Our study provides a fast and economical method to assess the administered dose on the facial mucosa on an individual basis.

Для цитирования: Duan Mengjie, Liu Li, Da Guillaume, Géhin Evelyne, Nielsen Peter V, Weinreich Ulla M, Lin Borong, Wang Yi, Zhang Ting, Sun Wei. Measuring the administered dose of particles on the facial mucosa of a realistic human model.. Indoor air. 2019. DOI: 10.1111/ina.12612.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.