Equivocal vs Positive Technetium-99m-Pyrophosphate Scintigraphy for Transthyretin Amyloid Cardiomyopathy: Comparing Outcomes, Demographics, and Imaging.

Chai Jocelyn, Cheung Matthew, Yim Jeffrey, Chen Lu Kun, Didi Ahmad, Balthazaar Shane J T, Yeung Darwin, Worsley Daniel, Davis Margot K

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Transthyretin cardiac amyloidosis (ATTR-CM) is an underdiagnosed infiltrative cardiomyopathy. Diagnosis is based on Technetium-99m-pyrophosphate-bone-scintigraphy scans (Tc-99m-PYP) with grades 2 to 3 classified as positive. The clinical significance of grade 1 (classified equivocal by American Society of Nuclear Cardiology) is unclear. We aimed to describe the differences in clinical/imaging characteristics among those with equivocal vs positive Tc-99m-PYP and to describe outcomes of further investigations.

METHODS

We performed a retrospective study of patients who underwent Tc-99m-PYP at 2 institutions between January 2017 and November 2022. Baseline demographics, laboratory, and imaging data were collected.

RESULTS

A total of 502 Tc-99m-PYP were performed with single-photon emission computed tomography (SPECT) 3 hours post-tracer injection: 347 (69%) negative, 46 (9%) equivocal, and 109 (22%) positive. In the latter 2 groups, the median age was 78 (interquartile range [IQR]: 72-84) years, and 38 (25%) were female. Average follow-up was 19.7 ± 14.6 months. No patients with equivocal scans were diagnosed with ATTR-CM. Equivocal scans had lower intraventricular septal diameters (11 mm [IQR: 10-11] vs 15 mm [IQR: 12-17]), larger left ventricular end-diastolic dimension (50 mm [IQR: 44-56] vs 43 mm [IQR: 40-50]), and more negative global longitudinal strain (-18.7 [IQR: -22.2 to -18.7] vs -13.8 [IQR: -17.9 to -10.9] %). Only 12 (26%) patients with equivocal scans underwent further imaging or biopsy. Of 2 patients with monoclonal gammopathy, 1 had AL-amyloidosis.

CONCLUSIONS

Our patients with equivocal grade 1 scans were not diagnosed with ATTR-CM. They exhibited distinct imaging compared to positive scans. Our findings suggest that ATTR-CM phenotype and equivocal scans may represent early ATTR-CM (ie, false negative) or false positives and should undergo further workup. Further research is needed to determine the significance of equivocal studies.

Для цитирования: Chai Jocelyn, Cheung Matthew, Yim Jeffrey, Chen Lu Kun, Didi Ahmad, Balthazaar Shane J T, Yeung Darwin, Worsley Daniel, Davis Margot K. Equivocal vs Positive Technetium-99m-Pyrophosphate Scintigraphy for Transthyretin Amyloid Cardiomyopathy: Comparing Outcomes, Demographics, and Imaging.. CJC open. 2025. DOI: 10.1016/j.cjco.2025.06.012.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.