Zhong nan da xue xue bao. Yi xue ban = Journal of Central South University. Medical sciences · 2015
[Anesthesia experiences on laparoscopic nephrectomy with da Vinci S robotics].
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Mou Ling, Lan Zhixun
Аннотация
OBJECTIVE: To summarize the clinical anesthesia experiences in 20 patients who underwent laparoscopic nephrectomy with da Vinci S robotics.
METHODS: Anesthesia data of 20 patients from Sichuan Provincial People's Hospital, who underwent laparoscopic nephrectomy with da Vinci S robotics from August 2014 to November 2014, were analyzed and summarized. The anesthesia time, operation time, CO(2) pneumoperitoneum time, PaCO(2) and PETCO(2) were recorded.
RESULTS: All patients were anesthetized and underwent surgery with da Vinci S robotics. The anesthesia time was (220±14) min, the operation time was (187±11) min, and the CO(2) pneumoperitoneum time was (180±13) min. The PaCO(2) and PETCO(2) were significantly elevated at 1.5 h after operation compared with those at the baseline (before pneumoperitoneum) (P<0.05). The pH value was significantly decreased at 2.5 h after operation compared to that at the baseline (P<0.05). The peak airway pressure of inspiration was significantly elevated at 0.5 h after the beginning of pneumoperitoneum compared to that at the baseline (P<0.05).
CONCLUSION: The hemodynamics is stable during the laparoscopic nephrectomy with da vinci S robotics. However, the duration of CO(2) pneumoperitoneum is significantly increased compared to that of other surgical procedures, resulting in high airway resistance and acid-base disturbance.
METHODS: Anesthesia data of 20 patients from Sichuan Provincial People's Hospital, who underwent laparoscopic nephrectomy with da Vinci S robotics from August 2014 to November 2014, were analyzed and summarized. The anesthesia time, operation time, CO(2) pneumoperitoneum time, PaCO(2) and PETCO(2) were recorded.
RESULTS: All patients were anesthetized and underwent surgery with da Vinci S robotics. The anesthesia time was (220±14) min, the operation time was (187±11) min, and the CO(2) pneumoperitoneum time was (180±13) min. The PaCO(2) and PETCO(2) were significantly elevated at 1.5 h after operation compared with those at the baseline (before pneumoperitoneum) (P<0.05). The pH value was significantly decreased at 2.5 h after operation compared to that at the baseline (P<0.05). The peak airway pressure of inspiration was significantly elevated at 0.5 h after the beginning of pneumoperitoneum compared to that at the baseline (P<0.05).
CONCLUSION: The hemodynamics is stable during the laparoscopic nephrectomy with da vinci S robotics. However, the duration of CO(2) pneumoperitoneum is significantly increased compared to that of other surgical procedures, resulting in high airway resistance and acid-base disturbance.