Harmonic scalpel versus electrocautery in breast reduction surgery: a randomized controlled trial.

Burdette Todd E, Kerrigan Carolyn L, Homa Karen A

Сравнительное исследованиеСтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

The authors hypothesized that the Harmonic Scalpel (Ethicon Endo-Surgery, Cincinnati, Ohio) might outperform electrocautery in bilateral breast reduction surgery, possibly resulting in (1) shorter operative times, (2) lower postoperative fluid drainage rates, and (3) reduced postoperative pain scores.

METHODS

Thirty-one patients were evaluated in a matched-pair design, with random (blinded) assignment of one side to the Harmonic Scalpel, with the other side defaulting to electrocautery. Main outcome measures were: (1) resection/hemostasis time, (2) drainage volume, and (3) postoperative pain. The authors also compared the learning curves, operative time versus specimen weights, complications, and costs for the devices.

RESULTS

There was a statistically significant (but not clinically significant) difference between the median times for the Harmonic Scalpel (33 minutes) and electrocautery (31 minutes) (p=0.02). There was no statistical difference in drainage scores, and pain scores were equivalent. The analysis of specimen weight versus resection/hemostasis time showed no correlation. There were more complications on the breasts reduced with the Harmonic device, but due to the small sample size, the complication results were not statistically significant. Start-up costs for the devices were comparable, but the per-procedure cost for the Harmonic device was considerably higher.

CONCLUSIONS

The Harmonic Scalpel is roughly equivalent to electrocautery in breast reduction surgery in terms of resection/hemostasis time, serous drainage, and postoperative pain. Though the Harmonic device may be excellent for other surgical procedures, its high cost suggests that surgeons and institutions can confidently forgo its use in breast reduction surgery.

CLINICAL QUESTION/LEVEL OF EVIDENCE: Therapeutic, II.

Для цитирования: Burdette Todd E, Kerrigan Carolyn L, Homa Karen A. Harmonic scalpel versus electrocautery in breast reduction surgery: a randomized controlled trial.. Plastic and reconstructive surgery. 2011. DOI: 10.1097/prs.0b013e318221da3e.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.