MedElevator Войти в исследования
← Поиск публикаций

DOI 10.6009/jjrt.2012_jsrt_68.9.1250

Медицинская библиотека · Nihon Hoshasen Gijutsu Gakkai zasshi · 2012

[Examination of the effectiveness of heart rate control using intravenous β-blocker in 64-slice coronary computed tomography angiography].

Yamaguchi Takayoshi, Takahashi Daichi, Nakagawa Shingo, Morita Mari, Noda Rie, Nakamura Yoko, Igarashi Keiichi

Сравнительное исследованиеАннотация на английскомСтатьяПеревод пока не подготовлен

Аннотация

The purpose of this study is to clarify the effectiveness of the use of β-blocker in coronary computed tomography angiography (CCTA). In 1783 patients, heart rate was controlled by propranolol injection to patients with heart rates of 61 bpm or more. As a result, the scan heart rate (58.8±6.5 bpm) decreased significantly compared with the initial heart rate (72.7±9.4 bpm). Prospective gating method was used by 61.9% including 64.3% of the intravenous β-blocker injection group. Moreover, daily use of oral β-blocker had influence on reduction of the scan heart rate (daily use group: 60.1±6.5 bpm vs. unuse group: 58.5±6.3 bpm p<0.01). When we evaluated the image quality of CCTA by the score, the improvement of the score was obviously admitted by 65 bpm or less of the scan heart rate. The ratio of scan heart rate that was controlled by 65 bpm or less was decreased in the initial heart rate groups that were 81 bpm or more. The incidence of adverse reactions by the propranolol injection was few, and these instances only involved slight symptoms. Therefore, heart rate control with the use of β-blocker is useful for the image quality improvement of CCTA. This form of treatment can be safely enforced.

Для цитирования: Yamaguchi Takayoshi, Takahashi Daichi, Nakagawa Shingo, Morita Mari, Noda Rie, Nakamura Yoko, Igarashi Keiichi. [Examination of the effectiveness of heart rate control using intravenous β-blocker in 64-slice coronary computed tomography angiography].. Nihon Hoshasen Gijutsu Gakkai zasshi. 2012. DOI: 10.6009/jjrt.2012_jsrt_68.9.1250.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.