Repeatability of the ciliary sulcus-to-sulcus diameter measurement using wide-scanning-field ultrasound biomicroscopy.

Yokoyama Sho, Kojima Takashi, Horai Rie, Ito Mayuka, Nakamura Tomoaki, Ichikawa Kazuo

Оценочное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate the interexaminer and intraexaminer variance in ciliary sulcus-to-sulcus (STS) diameter measurements using wide-scanning-field ultrasound biomicroscopy (UBM) (Vumax II).

SETTING

Nagoya Eye Clinic, Nagoya, Japan.

DESIGN

Evaluation of diagnostic test or technology.

METHOD: Two examiners measured the STS diameter 10 times in each subject. Intraexaminer and interexaminer variances were calculated. To determine interexaminer variance at each UBM measurement step, the examiner was changed every 2 steps when the STS diameter was measured. The Bland-Altman plot test was used to analyze each step of measurement variance.

RESULTS

Thirty eyes of 15 volunteers (9 men, 6 women; mean age 29.6 years ± 6.2 [SD]) were enrolled. The mean coefficient of variation was 0.62% ± 0.20% for intraexaminer measurements and 3.4% ± 2.4% for interexaminer measurements. There were statistically significant differences between the 2 examiners in the step of extracting images and determining and measuring the STS diameter (P=.02). The 95% confidence intervals in all steps were relatively high (recordings, -1.02 to 1.08 mm; extracting images and determining and measuring STS; -0.79 to 1.25 mm).

CONCLUSION

Interexaminer variance in STS measurement should be considered if the STS diameter is used for selecting the size of posterior chamber phakic intraocular lenses.

Для цитирования: Yokoyama Sho, Kojima Takashi, Horai Rie, Ito Mayuka, Nakamura Tomoaki, Ichikawa Kazuo. Repeatability of the ciliary sulcus-to-sulcus diameter measurement using wide-scanning-field ultrasound biomicroscopy.. Journal of cataract and refractive surgery. 2011. DOI: 10.1016/j.jcrs.2011.01.024.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.