MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3748/wjg.14.6204

Медицинская библиотека · World journal of gastroenterology · 2008

Hydrogen breath test for the diagnosis of lactose intolerance, is the routine sugar load the best one?

Argnani Fiorenza, Di Camillo Mauro, Marinaro Vanessa, Foglietta Tiziana, Avallone Veronica, Cannella Carlo, Vernia Piero

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

AIM: To evaluate the prevalence of lactose intolerance (LI) following a load of 12.5 g in patients diagnosed as high-grade malabsorbers using the hydrogen breath test (HBT)-25.

METHODS

Ninety patients showing high-grade malabsorption at HBT-25 were submitted to a second HBT with a lactose load of 12.5 g. Peak hydrogen production, area under the curve of hydrogen excretion and occurrence of symptoms were recorded.

RESULTS

Only 16 patients (17.77%) with positive HBT-25 proved positive at HBT-12.5. Hydrogen production was lower as compared to HBT-25 (peak value 21.55 parts per million (ppm) +/- 29.54 SD vs 99.43 ppm +/- 40.01 SD; P < 0.001). Symptoms were present in only 13 patients. The absence of symptoms during the high-dose test has a high negative predictive value (0.84) for a negative low-dose test. The presence of symptoms during the first test was not useful for predicting a positive low-dose test (positive predictive value 0.06-0.31).

CONCLUSION

Most patients with a positive HBT-25 normally absorb a lower dose of lactose and a strict lactose restriction on the basis of a "standard" HBT is, in most instances, unnecessary. Thus, the 25 g lactose tolerance test should probably be substituted by the 12.5 g test in the diagnosis of LI, and in providing dietary guidelines to patients with suspected lactose malabsorption/intolerance.

Для цитирования: Argnani Fiorenza, Di Camillo Mauro, Marinaro Vanessa, Foglietta Tiziana, Avallone Veronica, Cannella Carlo, Vernia Piero. Hydrogen breath test for the diagnosis of lactose intolerance, is the routine sugar load the best one?. World journal of gastroenterology. 2008. DOI: 10.3748/wjg.14.6204.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.