MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.cgh.2006.06.009

Медицинская библиотека · Clinical gastroenterology and hepatology : the official clinical practice journal of the American Gastroenterological Association · 2006

Comparison of a real-time polymerase chain reaction assay for lactase genetic polymorphism with standard indirect tests for lactose maldigestion.

Szilagyi Andrew, Malolepszy Paula, Hamard Elise, Xue Xiaoqing, Hilzenrat Nir, Ponniah Mary, MacNamara Elizabeth, Chong George

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND & AIMS: There is a discrepancy in outcome between the lactose tolerance and breath hydrogen tests for lactose maldigestion. The availability of a validated genetic test for lactase polymorphism allows a reevaluation of these tests.

METHODS

Thirty healthy adults participated in a 50-g lactose challenge test at a university clinic. Blood was drawn for genetic and timed blood glucose testing (2 hours), and breath hydrogen was measured (4.5 hours). Lactase genetic polymorphism was assessed by a real-time polymerase chain reaction assay. Participants completed a diet questionnaire, and symptoms were recorded during the lactose challenge. Sensitivity and specificity were calculated for each indirect test. The 2-way kappa coefficient between these tests was evaluated. Student t test and Wilcoxon rank sum test were used to compare variables.

RESULTS

The lactose tolerance test as a standard had an 87.5% sensitivity and 92.7% specificity for genetic status. Only a moderate agreement between lactose tolerance test and breath hydrogen test was observed (2-way kappa coefficient, .53; 95% confidence interval, .22-.83). When genetic status was used as standard, symptoms had a moderate sensitivity and specificity. Lactose tolerance test had very good sensitivity, and the breath test had excellent specificity.

CONCLUSIONS

Both indirect tests independently have good to very good sensitivities and specificities for genetic lactase status. The noted disagreement likely reflects variables that affect the tests independently of intestinal lactase status. The value of these tests in the light of the availability of genetic testing is discussed.

Для цитирования: Szilagyi Andrew, Malolepszy Paula, Hamard Elise, Xue Xiaoqing, Hilzenrat Nir, Ponniah Mary, MacNamara Elizabeth, Chong George. Comparison of a real-time polymerase chain reaction assay for lactase genetic polymorphism with standard indirect tests for lactose maldigestion.. Clinical gastroenterology and hepatology : the official clinical practice journal of the American Gastroenterological Association. 2006. DOI: 10.1016/j.cgh.2006.06.009.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.