MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1136/bjo.2003.036715

Медицинская библиотека · The British journal of ophthalmology · 2004

Quantitative evaluation of changes in anterior segment biometry by peripheral laser iridotomy using newly developed scanning peripheral anterior chamber depth analyser.

Kashiwagi K, Abe K, Tsukahara S

Оценочное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

AIM: Using the newly developed scanning peripheral anterior chamber depth analyser (SPAC), the effects of peripheral laser iridotomy (PLI) on peripheral anterior chamber depth (PACD) were determined quantitatively as was the association between PACD and chronic elevation of intraocular pressure (IOP) after PLI.

METHODS

16 eyes of 15 patients with acute primary angle closure glaucoma (PACG) attack, 14 eyes of 14 patients with narrow angle and PACG attack in their fellow eyes, and 13 eyes of seven patients with chronic angle closure glaucoma (CACG) were enrolled. The SPAC scanned the anterior ocular segment from the optical axis to the limbus and took 21 consecutive slit lamp images at 0.4 mm intervals. A computer installed program automatically evaluated the PACD and the averaged values of three measurements were employed for analysis.

RESULTS

PLI significantly increased PACD and changed the iris contour from convex to flat or concave in all the enrolled eyes. The extent of the PLI induced PACD increase was enhanced with increasing distance from the optical axis. Comparing PACDs after PLI, eyes that received prophylactic PLI showed the greatest extent of PLI induced PACD increase, followed by eyes with CACG and eyes with PACG attack. The PACD of eyes with PACG attack was almost the same as that of the fellow eyes of PACG attack before prophylactic PLI. Eyes with PACG attack showed poorer IOP control after PLI than eyes with narrow angle and CACG with PLI.

CONCLUSIONS

PLI significantly increases PACD and the small PLI induced opening of PACD may contribute to chronic IOP elevation after PLI.

Для цитирования: Kashiwagi K, Abe K, Tsukahara S. Quantitative evaluation of changes in anterior segment biometry by peripheral laser iridotomy using newly developed scanning peripheral anterior chamber depth analyser.. The British journal of ophthalmology. 2004. DOI: 10.1136/bjo.2003.036715.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.