DOI 10.1177/19322968261427798

Медицинская библиотека · Journal of diabetes science and technology · 2026

Association Between Real-Time Continuous Glucose Monitoring Sensor Active Time and Glycemic Metrics in Patients With Diabetes: A Real-World Setting Analysis.

Alzubaidi Lamya, Alenezi Faisal, Alsoheimi Abdullah, Arabe Abdullah, Alrshood Amera, Hassanein Muna, Bakhsh Abdulmohsen

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Consistent use of continuous glucose monitoring (CGM) systems improves glycemic control compared with occasional use. We aimed to assess the association between the percent time sensor was active and glycemic metrics, among patients with diabetes using the FreeStyle Libre 2 Plus CGM System.

METHODS

De-identified CGM data from 12 162 readers of patients with diabetes in Saudi Arabia, between January 2023 and September 2024, were analyzed. Readings were grouped into five sensor usage quintiles. For each quintile, average glycemic metrics were summarized, including mean glucose, glucose management indicator (GMI), time in range (TIR), time below range (TBR), time above range (TAR), and glycemia risk index (GRI). The Jonckheere-Terpstra trend test was used to assess monotonic trends between sensor usage time and glycemic metrics.

RESULTS

As sensor use increased, there were significant decreases in GRI (Std. J-T = -29.672), average blood glucose (Std. J-T = -23.985), GMI (Std. J-T = -23.949), and TAR (Std. J-T = -21.964). Time below range showed a different pattern, with an initial increase followed by a decline from the third quantile as sensor usage increased (Std. J-T = -4.903). Time in range increased significantly with greater sensor usage (Std. J-T = 25.428; all P-values <.001).

CONCLUSION

In real-world settings, higher CGM use was associated with better glycemic outcomes, including lower GRI, lower average blood glucose, lower GMI, lower TAR, lower TBR, and higher TIR. Future studies should examine factors influencing sensor use to inform strategies that promote effective CGM adoption.

Для цитирования: Alzubaidi Lamya, Alenezi Faisal, Alsoheimi Abdullah, Arabe Abdullah, Alrshood Amera, Hassanein Muna, Bakhsh Abdulmohsen. Association Between Real-Time Continuous Glucose Monitoring Sensor Active Time and Glycemic Metrics in Patients With Diabetes: A Real-World Setting Analysis.. Journal of diabetes science and technology. 2026. DOI: 10.1177/19322968261427798.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.