Assessment of cerebral perfusion in moyamoya disease with dynamic pseudo-continuous arterial spin labeling using a variable repetition time scheme with optimized background suppression.

Togao Osamu, Obara Makoto, Yamashita Koji, Kikuchi Kazufumi, Arimura Koichi, Nishimura Ataru, Nakamizo Akira, Wada Tatsuhiro, Tokunaga Chiaki, Mikayama Ryoji, Yamashita Yasuo, Hamano Hiroshi, Van Cauteren Marc, Ishigami Kousei, Baba Shingo

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: Accurate assessment of cerebral perfusion in moyamoya disease is necessary to determine the indication for treatment. We aimed to investigate the usefulness of dynamic PCASL using a variable TR scheme with optimized background suppression in the evaluation of cerebral perfusion in moyamoya disease.

METHODS

We retrospectively analyzed the images of 24 patients (6 men and 18 women, mean age 31.4 ± 18.2 years) with moyamoya disease; each of whom was imaged with both dynamic PCASL using the variable-TR scheme and 123IMP SPECT with acetazolamide challenge. ASL dynamic data at 10 phases are acquired by changing the LD and PLD. The background suppression timing was optimized for each phase. CBF and ATT were measured with ASL, and CBF and CVR to an acetazolamide challenge were measured with SPECT.

RESULTS

A significant moderate correlation was found between the CBF measured by dynamic PCASL and that by SPECT (r = 0.53, P < 0.001). The CBF measured by dynamic PCASL (52.5 ± 13.3 ml/100 mg/min) was significantly higher than that measured by SPECT (43.0 ± 12.6 ml/100 mg/min, P < 0.001). The ATT measured by dynamic PCASL showed a significant correlation with the CVR measured by SPECT (r = 0.44, P < 0.001). ATT was significantly longer in areas where the CVR was impaired (CVR < 18.4%, ATT = 1812 ± 353 ms) than in areas where it was preserved (CVR > 18.4%, ATT = 1301 ± 437 ms, P < 0.001). The ROC analysis showed a moderate accuracy (AUC = 0.807, sensitivity = 87.7%, specificity = 70.4%) when the cutoff value of ATT was set at 1518 ms.

CONCLUSION

Dynamic PCASL using this scheme was found to be useful for assessing cerebral perfusion in moyamoya disease.

Для цитирования: Togao Osamu, Obara Makoto, Yamashita Koji, Kikuchi Kazufumi, Arimura Koichi, Nishimura Ataru, Nakamizo Akira, Wada Tatsuhiro, Tokunaga Chiaki, Mikayama Ryoji, Yamashita Yasuo, Hamano Hiroshi, Van Cauteren Marc, Ishigami Kousei, Baba Shingo. Assessment of cerebral perfusion in moyamoya disease with dynamic pseudo-continuous arterial spin labeling using a variable repetition time scheme with optimized background suppression.. Neuroradiology. 2022. DOI: 10.1007/s00234-022-03095-5.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.